Optical techniques for recording and manipulating cellular electrophysiology have advanced rapidly in just a few decades. These developments allow for the analysis of cardiac cellular dynamics at multiple scales while largely overcoming the drawbacks associated with the use of electrodes. The recent advent of optogenetics opens up new possibilities for regional and tissue-level electrophysiological control and hold promise for future novel clinical applications. This article, which emerged from the international NOTICE workshop in 2018, reviews the state-of-the-art optical techniques used for cardiac electrophysiological research and the underlying biophysics. The design and performance of optical reporters and optogenetic actuators are reviewed along with limitations of current probes. The physics of light interaction with cardiac tissue is detailed and associated challenges with the use of optical sensors and actuators are presented. Case studies include the use of fluorescence recovery after photobleaching and super-resolution microscopy to explore the micro-structure of cardiac cells and a review of two photon and light sheet technologies applied to cardiac tissue. The emergence of cardiac optogenetics is reviewed and the current work exploring the potential clinical use of optogenetics is also described. Approaches which combine optogenetic manipulation and optical voltage measurement are discussed, in terms of platforms that allow real-time manipulation of whole heart electrophysiology in open and closed-loop systems to study optimal ways to terminate spiral arrhythmias. The design and operation of optics-based approaches that allow high-throughput cardiac electrophysiological assays is presented. Finally, emerging techniques of photo-acoustic imaging and stress sensors are described along with strategies for future development and establishment of these techniques in mainstream electrophysiological research.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8637189 | PMC |
http://dx.doi.org/10.3389/fphys.2021.769586 | DOI Listing |
Spectrochim Acta A Mol Biomol Spectrosc
February 2025
Institute for Medical Research, National Institute of Republic of Serbia, University of Belgrade, Belgrade, Serbia. Electronic address:
RBCs deformability plays a crucial role in maintaining proper blood flow and oxygen delivery throughout the body. Conventional ektacytometry fails to differentiate between variations in deformability of RBC subpopulations as the averaging measurement process obscures these differences. In this study, we introduced an approach that integrates label-free optics-based techniques (flow cytometry, phase-contrast, and two-photon excitation fluorescent microscopy) with ektacytometry to evaluate subpopulations that exhibit decreased RBCs deformability upon an in vitro oxidation using 0.
View Article and Find Full Text PDFRadio-frequency orbital angular momentum (RF-OAM) mode multiplexing has received increasing attention in next-generation (6G) wireless communication as a new spatial multiplexing dimension to further extend data capacity. In particular, the circular antenna array (CAA) based RF-OAM generation using photonic methods is a promising approach due to its flexible reconfigurability, low propagation loss, high operating bandwidth, and high pattern quality. However, most current reports focus either on the bulk optics-based implementations or on band-limited delay line-based approaches.
View Article and Find Full Text PDFSci Rep
September 2024
Key Laboratory of Particle and Radiation Imaging of Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing, 100084, China.
Methods Appl Fluoresc
July 2024
Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76109, United States of America.
Continuous in-line detection and process monitoring are essential for industrial, analytical, and biomedical applications. Lightweight, highly flexible, and low-cost fiber optics enable the construction of compact and robust hand-held devices forchemical and biological species analysis in both industrial and biomedical/detection. Despite the broad range of fiber-optic based applications, we lack a good understanding of the parameters that govern the efficiency of light collection or the sensitivity of detection.
View Article and Find Full Text PDFJ Am Chem Soc
May 2024
Department of Chemistry and Biochemistry, Kent State University, Kent, Ohio 44242, United States.
The ability to controllably move gaseous ions is an essential aspect of ion-based spectrometry (, mass spectrometry and ion mobility spectrometry) as well as materials processing. At higher pressures, ion motion is largely governed by diffusion and multiple collisions with neutral gas molecules. Thus, high-pressure ion optics based on electrostatics require large fields, radio frequency drives, complicated geometries, and/or partially transmissive grids that become contaminated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!