Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background/aims: The objective of this study was to determine whether the newly developed two-dimensional shear wave elastography (2D-SWE, RS85, Samsung-shearwave imaging) was more valid and reliable than transient elastography (TE) for predicting the stage of liver fibrosis.
Methods: The study prospectively enrolled a total of 116 patients with chronic liver disease who underwent 2D-SWE, TE, laboratory testing, and liver biopsy on the same day from two tertiary care hospitals. One patient with unreliable measurement was excluded. The measurement of 2D-SWE was considered acceptable when a homogenous color pattern in a region of interest of at least 10 mm was detected at 10 different sites. Diagnostic performance was calculated using area under the receiver operating characteristic curve (AUROC).
Results: Liver fibrosis stages included F0 (18%), F1 (19%), F2 (24%), F3 (22%), and F4 (17%). Interclass correlation coefficient for inter-observer agreement in 2D-SWE was 0.994 (95% confidence interval [CI], 0.988 to 0.997). Overall, the results of 2D-SWE and stages of histological fibrosis were significantly correlated (r = 0.601, p < 0.001). For The 2D-SWE showed good diagnostic ability (AUROC, 0.851; 95% CI, 0.773 to 0.911) comparable to TE (AUROC, 0.859; 95% CI, 0.781 to 0.916) for the diagnosis of significant fibrosis (≥ F2), and the cut-off value was 5.8 kPa. AUROC and optimal cut-off of 2D-SWE for the diagnosis of liver cirrhosis were 0.889 (95% CI, 0.817 to 0.940) and 9.6 kPa, respectively. TE showed similar diagnostic performance in distinguishing cirrhosis (AUROC, 0.938; 95% CI, 0.877 to 0.974; p = 0.08).
Conclusion: 2D-SWE is comparable to TE in diagnosing significant fibrosis and liver cirrhosis with high reliability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8925940 | PMC |
http://dx.doi.org/10.3904/kjim.2020.635 | DOI Listing |