Objective: The objective of this investigation was to create and validate 5-point photonumeric scales for the assessment of dynamic crow's feet, static crow's feet, and infraorbital hollows.

Material And Methods: Three novel 5-point photonumeric scales were created by a medical team. A total of 12 raters from all over the world performed a digital validation, and a total of 5 raters a live validation of the created scale.

Results: The statistical analysis revealed almost perfect intra-rater and inter-rater reliability in the digital validation of the scales for the assessment of static and dynamic crow's feet as well as infraorbital hollows. In the live validation, both crow's feet scales showed almost perfect intra-rater reliability, while the Croma Infraorbital Hollow Assessment Scale showed substantial intra-rater reliability. Inter-rater reliability was substantial for all three scales in the live validation. All three scales, the Croma Dynamic Crow's Feet Assessment Scale, Croma Static Crow's Feet Assessment Scale, and Croma Infraorbital Hollow Assessment Scale, were validated digitally and in a live setting.

Conclusion: The created scales to assess infraorbital hollowing, dynamic and static crow's feet have been shown to provide substantial to almost perfect agreement in the digital and live validation and can thus be considered as helpful tools in the clinical and research setting. While technical methods and appliances to assess the degrees of severity of age-dependent features are advancing, validated scales are of great importance due to their ease of use and, as shown by the validations, reliability, and reproducibility.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocd.14643DOI Listing

Publication Analysis

Top Keywords

crow's feet
28
live validation
16
assessment scale
16
5-point photonumeric
12
photonumeric scales
12
scales assessment
12
dynamic crow's
12
static crow's
12
scales
9
total raters
8

Similar Publications

Objectives: The concept of beauty from within is a growing trend in the market and people now look for oral supplements that can enhance the well-being of skin from within. Within this principle, a proprietary pomegranate extract (Grantria), standardized to ellagic acid, punicic acid and punicalagin, was developed using ADOP (Advanced Oil-Powder) technology and was clinically evaluated for its efficacy and safety in healthy adults.

Methods: This evaluation was carried out as a randomized, placebo-controlled clinical study for 60 days at a daily dose of 300 mg.

View Article and Find Full Text PDF

Background: Noninvasive aesthetic procedures for facial rejuvenation are gaining popularity. Conventional treatments, such as radiofrequency (RF) and high-intensity focused ultrasound (HIFU), primarily improve skin quality but do not address the deeper musculoaponeurotic structures that affect facial laxity. A novel approach that delivers synchronized RF with high intensity facial electrical stimulation (HIFES) thought to target both the skin and underlying musculoaponeurotic framework to effectively enhance facial laxity has been investigated.

View Article and Find Full Text PDF

Background: FACE-Q Aesthetics scales assess patient-important outcomes following both surgical/nonsurgical facial cosmetic interventions. Convergent validity is the degree to which the scores of one measurement relate to another measuring a similar construct.

Objectives: This study aims to establish the convergent validity of 11 FACE-Q Aesthetics appearance scales using the MERZ Aesthetics scales.

View Article and Find Full Text PDF

Modified Infrabrow Blepharoplasty for Periorbital Rejuvenation in Asia Women.

J Craniofac Surg

December 2024

Department of Plastic Surgery, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou.

Objective: The infrabrow blepharoplasty is a common surgical operation indicated in Asians for periorbital rejuvenation. This operation alone is difficult to achieve the correction of crow's feet. Therefore, the authors elucidate the authors' experiences of applying infrabrow blepharoplasty combined with the subcutaneous undermining of the lateral periorbital region to treat upper eyelid dermatochalasis with lateral hooding deformity and alleviate crow's feet, including its indications, operative procedures, and postoperative outcomes.

View Article and Find Full Text PDF

Background: The function of injectable hyaluronic acid-based fillers is to smooth dermal wrinkles formed during aging. The aim of this study is to evaluate the performance and safety of a dermal filler after its commercialization.

Methods: In this context, an 18-month prospective randomized single-blind study for the efficacy and safety of ART FILLER Fine Lines (AFFL) was performed on the forehead, the upper lip, the cheek folds, and the crow's feet.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!