A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Overcoming challenges in refining the current generation of coronary stents. | LitMetric

Introduction: Late stent thrombosis caused by delayed vascular healing and prolonged local inflammation were major drawbacks of 1 generation drug-eluting stents (DES). Strut design, biocompatibility of polymer, and drug-release profiles were improved in 2 and 3rdgeneration DES. Accordingly, the indications for percutaneous coronary intervention with DES have been expanded to more complex patients and lesions. Despite these improvements, significant barriers such as greater flexibility in the duration of dual-antiplatelet therapy (DAPT) as well as reducing long-term stent-related events remain. To achieve ideal short- and long-term results, these existing limitations need to be overcome.

Areas Covered: We will discuss the current limitations of coronary DES and how they might be overcome from pathological and clinical viewpoints.

Expert Opinion: Optimizing DAPT duration after stent implantation and prevention of in-stent neoatherosclerosis are two major issues in current DES. Overcoming these drawbacks is a prerequisite toward achieving better short- and long-term clinical outcomes. New technologies including platform design, polymer types, and anti-proliferative agent itself might lead to further improvements. Although the initial experience with bioresorbable scaffold/stents (BRS) was disappointing, positive results of clinical studies regarding novel BRS are raising expectations. Overall, further device innovation is desired for overcoming the limitations of current DES.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14779072.2021.2013810DOI Listing

Publication Analysis

Top Keywords

short- long-term
8
current des
8
des
6
overcoming challenges
4
challenges refining
4
current
4
refining current
4
current generation
4
generation coronary
4
coronary stents
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!