A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Indoor humidity levels and associations with reported symptoms in office buildings. | LitMetric

Moderate indoor relative humidity (RH) levels (i.e., 40%-60%) may minimize transmission and viability of some viruses, maximize human immune function, and minimize health risks from mold, yet uncertainties exist about typical RH levels in offices globally and about the potential independent impacts of RH levels on workers' health. To examine this, we leveraged one year of indoor RH measurements (which study participants could view in real time) in 43 office buildings in China, India, Mexico, Thailand, the United Kingdom, and the United States, and corresponding self-report symptom data from 227 office workers in a subset of 32 buildings. In the buildings in this study, 42% of measurements during 9:00 - 17:00 on weekdays were less than 40% RH and 7% exceeded 60% RH. Indoor RH levels tended to be lower in less tropical regions, in winter months, when outdoor RH or temperature was low, and late in the workday. Furthermore, we also found statistically significant evidence that higher indoor RH levels across the range of 14%-70% RH were associated with lower odds of reporting dryness or irritation of the throat and skin among females and unusual fatigue among males in models adjusted for indoor temperature, country, and day of year.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10924614PMC
http://dx.doi.org/10.1111/ina.12961DOI Listing

Publication Analysis

Top Keywords

humidity levels
8
office buildings
8
indoor levels
8
indoor
6
levels
6
indoor humidity
4
levels associations
4
associations reported
4
reported symptoms
4
symptoms office
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!