Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: In pattern-specific scoliosis exercises and bracing, the corrective treatment plan differs according to different curve patterns. There are a limited number of studies investigating the reliability of the commonly used classifications systems.
Objective: To test the reliability of the augmented Lehnert-Schroth (ALS) classification and the Rigo classification.
Methods: X-rays and posterior photographs of 45 patients with scoliosis were sent by the first author to three clinicians twice at 1-week intervals. The clinicians classified images according to the ALS and Rigo classifications, and the data were analysed using SPSS V-16. Intraclass correlation coefficients (ICCs) and standard error measurement (SEM) were calculated to evaluate the inter- and intra-observer reliability.
Results: The inter-observer ICC values were 0.552 (ALS), 0.452 (Rigo) for X-ray images and 0.494 (ALS), 0.518 (Rigo) for the photographs. The average intra-observer ICC value was 0.720 (ALS), 0.581 (Rigo) for the X-ray images and 0.726 (ALS) and 0.467 (Rigo) for the photographs.
Conclusions: The results of our study indicate moderate inter-observer reliability for X-ray images using the ALS classification and clinical photographs using the Rigo classification. Intra-observer reliability was moderate to good for X-ray images and clinical photographs using the ALS classification and poor to moderate for X-ray and clinical photographs using the Rigo classification.
Clinical Implications: Pattern classifications assist in creating a plan and indication of correction in specific scoliosis physiotherapy and pattern-specific brace applications and surgical treatment. More sub-types are needed to address the individual patterns of curvature. The optimisation of curve classification will likely reduce failures in diagnosis and treatment.