Objectives: The primary aim of this study was to assess the linear and geometric accuracy of 3-dimensional (3D) printed tooth replicas when compared to the actual tooth. The secondary aims were to compare the accuracy of three different 3D printers and to evaluate dimensional changes of tooth replicas after sterilization.

Methods: A sample of 16 teeth were selected from recruited patients. Segmentation was carried out to generate files from the patient's cone beam computed tomography (CBCT) data, Tooth replicas were then printed using three printers making use of Polyjet, laser stereolithography (SLA) and digital light processing (DLP) technology respectively. These replicas, along with the actual tooth, were scanned by an optical scanner. Replicas were sent for sterilization and scanned again. Paired superimposition of the scans was performed.

Results: A mean length difference of 0.36 mm and mean geometric (root mean square [RMS]) difference of 0.56 mm was found. Qualitative analysis showed that the replicas were generally larger in size. Repeated ANOVA tests showed that the Polyjet printer had the highest accuracy (p<0.0001). After sterilization, there was an overall mean length difference of 0.10 mm and RMS deviation of 0.02 mm.

Conclusion: This study found that there was a significant difference in linear and geometric measurements of the tooth replicas when compared to the actual tooth. This study also provides evidence that the printer which made use of Polyjet technology was able to produce more accurate models than SLA or DLP printers. Printed tooth models demonstrated clinically insignificant changes after heat sterilization.

Clinical Significance: 3D printed tooth replicas derived from the patient's CBCT data may be used in autotransplantation to increase predictability of the procedure. In order for this novel digital approach to realize its potential, it is critical to address questions as to how accurate the various printing technologies are in fabricating replicas.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2021.103908DOI Listing

Publication Analysis

Top Keywords

tooth replicas
16
cone beam
8
beam computed
8
computed tomography
8
tomography cbct
8
actual tooth
8
three printers
8
replicas
7
tooth
6
evaluation accuracy
4

Similar Publications

Article Synopsis
  • The management of molar-incisor hypomineralization is complex due to varying clinical appearances and treatment needs.
  • The report details a treatment case involving a carious permanent molar using glass ionomer cement (GIC) and an occlusal replica technique.
  • After the procedure, the patient showed no symptoms, maintained good oral hygiene, and the restorative material remained intact after 12 months.
View Article and Find Full Text PDF

Aim: This report highlights successful management of a rare case of a mandibular premolar with Oehler's Type IIIb Dens Invaginatus (DI) and peri-invagination periodontitis with guided intentional replantation (IR) without root canal treatment.

Methods: A 22-year-old female patient reported with discomfort and a sinus tract associated with tooth #21. Clinical examination and cone beam computed tomography revealed tooth #21 had an Oehler's Type IIIb DI with peri-invagination periodontitis.

View Article and Find Full Text PDF

Introduction: Guided surgery for immediate anterior implants aims to reduce the time required for aesthetic and functional immediate loading. However, the limited surface area of anterior teeth for guide stabilization may affect the accuracy of implant positioning. This in vitro study evaluated the effect of the number of supporting teeth on the accuracy of immediate implants in the maxillary central incisor region.

View Article and Find Full Text PDF

Background: The success of a restoration largely depends on the quality of its fit. This study aimed to investigate the fit quality of monolithic zirconia veneers (MZVs) produced through traditional and digital workflows.

Methods: A typodont maxillary right central incisor was prepared.

View Article and Find Full Text PDF

Objective: This study aimed to assess and compare the internal fit of custom-made posts and cores fabricated using digital impressions (DI) and conventional vinyl polysiloxane (VPS) impressions in restorative dentistry.

Materials And Methods: A typodont tooth model, simulating the anatomy of the root canal of a central incisor, was utilized for the study. Two groups were formed, Group A and Group B, and each group provided a total of 18 impressions of two types: DIs and VPS impressions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!