Development and assessment of an x-ray tube-based multi-beam x-ray scatter projection imaging system.

Rev Sci Instrum

Department of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada.

Published: November 2021

Coherent scatter x-ray imaging systems are sensitive to material structure and chemical composition, and generate soft-material images with contrast superior to conventional transmission x-ray imaging. For practicality in medical or security applications, the image data acquisition time should be <10 min. Our approach is a multi-beam projection imaging design. Previously, as a development stage, we implemented a synchrotron-based system with five coplanar pencil beams and continuous motion of the object. In the work reported here, we developed a more practical coherent scatter projection imaging system using a conventional x-ray tube source. The object is irradiated by an array of up to three rows by five columns of pencil beams, and motorized stages translate the object through the beams for step-and-shoot acquisition. For the same tube loading, broad spectrum beams, such as 110 kVp filtered with 2.25 mm Al, were found to provide a higher signal-difference-to-noise ratio between soft materials in scatter images than lower kVp, more heavily filtered beams that have a narrower, lower intensity spectrum. The shortest acquisition time for a 6.0 × 10.0 cm object with 6000 pixels was 8.8 min. The width of a sharp edge in the scatter image was consistent with the pencil beam diameter. Contrast-detail performance was similar to our synchrotron-based system. In this first x-ray tube-based system, for simplicity, the transmitted x rays are measured through attenuators using the same flat-panel detector that measures scattered x rays. As a result, the primary image quality was reduced.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0055900DOI Listing

Publication Analysis

Top Keywords

x-ray imaging
8
development assessment
4
x-ray
4
assessment x-ray
4
x-ray tube-based
4
tube-based multi-beam
4
multi-beam x-ray
4
x-ray scatter
4
scatter projection
4
projection imaging
4

Similar Publications

The position of the mental foramen is reported to change with age. This study aimed to examine age-related changes in the position of the mental foramen in men and women. Among 200 cases (age 21-100 years; 400 foramina) that underwent postmortem computed tomography, 109 (age 21-93 years; 218 foramina) with mandibular first and second premolars were examined using image analysis software to classify the position of the mental foramen according to Fishel's classification, and the χ² test was performed.

View Article and Find Full Text PDF

Diagnostic criteria for temporomandibular joint osteoarthritis using standardized uptake value in single-photon emission computed tomography-computed tomography.

Sci Rep

December 2024

Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Gangnam Severance Hospital, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Republic of Korea.

This study aimed to investigate the cutoff values of standardized uptake values (SUVs) and their accuracy using single-photon emission computed tomography-computed tomography (SPECT-CT) for temporomandibular joint (TMJ) osteoarthritis (OA) based on magnetic resonance imaging (MRI) and clinical examination. We included 106 joints of 53 patients with TMJ OA. SUVmax and SUVpeak of each TMJ was measured.

View Article and Find Full Text PDF

tumour specific surgery in colon cancer is gaining popularity among colorectal surgeons. Many advocate adapting surgical technique based on preoperative CT staging as not all patients require complete mesocolic excision (CME) and D3 lymphadenectomy. We aimed to assess the sensitivity and specificity of preoperative CT scans in nodal staging and analyse whether inadequate CT staging could have influenced local recurrences.

View Article and Find Full Text PDF

Introduction: Diabetes mellitus (DM) is a chronic metabolic disorder that increases fragility fracture risk. Conventional DXA-based areal bone mineral density (aBMD) assessments often underestimate this risk. Cortical Backscatter (CortBS) ultrasound, a radiation-free technique, non-invasively analyzes cortical bone's viscoelastic and microstructural properties.

View Article and Find Full Text PDF

Background: Veno-arterial (V-A) extracorporeal membrane oxygenation (ECMO) is commonly used for patients with cardiac arrest, cardiogenic shock, or heart failure and is a life-saving technique. Computed tomography angiography (CTA) examination in patients on ECMO presents certain challenges. Due to the dual circulation characteristics of blood flow in ECMO patients, vascular imaging and interpretation can be difficult and may even present pitfalls.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!