A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

PATIENT DOSES IN WHOLE-BODY PET/CT EXAMINATIONS IN THE LARGEST TERTIARY HOSPITAL IN GREECE. | LitMetric

AI Article Synopsis

  • The study assessed radiation doses from PET/CT exams at a major hospital in Greece, focusing on data from 1014 patients.
  • The average computed tomography dose index (CTDIvol) was 5.5 mGy and the dose length product (DLP) averaged 483.3 mGy·cm, both within established literature ranges.
  • These findings can serve as a reference until national guidelines for radiation doses in whole-body PET/CT scans are developed.

Article Abstract

The purpose of this study was to determine the patient radiation dose in combined whole-body positron emission tomography/computed tomography (PET/CT) examinations performed in the largest tertiary hospital in Greece. Computed tomography dose index (CTDIvol), dose length product (DLP), weight, height and administered activity of 2-[18F] fluoro-2-deoxy-D-glucose values for PET/CT examinations were recorded in a sample of 1014 randomly selected patients. The mean (±standard deviation) and median (interquartile) CTDIvol values were equal to 5.5 ± 2.4 and 4.8 (2.5) mGy, respectively. The respective DLP values were 483.3 ± 212.4 and 426 (234.6) mGy·cm. For the administered activity, mean and median were equal to 363.9 ± 68.3 and 361.6 (85.6) MBq. The mean administered activity per body weight was 4.8 ± 0.6 and the median 4.8 (0.6) MBq/kg. The results of this survey are within the range of values reported in the literature and can be used as a standard of reference until national diagnostic reference levels are established for whole-body PET/CT procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncab169DOI Listing

Publication Analysis

Top Keywords

pet/ct examinations
12
administered activity
12
whole-body pet/ct
8
largest tertiary
8
tertiary hospital
8
hospital greece
8
patient doses
4
doses whole-body
4
pet/ct
4
examinations largest
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!