A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of rigid and deformable coregistration between mpMRI and CT images in radiotherapy of prostate bed cancer recurrence. | LitMetric

Purpose: To evaluate the accuracy of rigid coregistration between multiparametric magnetic resonance (mpMR) and computed tomography (CT) images for radiotherapy of prostate bed cancer recurrence.

Materials And Method: Fifty-three patients (59 nodules) accrued in a prospective study on salvage radiotherapy for prostatic bed recurrence were suitable for the analysis. Patients underwent a pre radiotherapy mpMR exam and a planning CT in the same treatment position and with control of organ filling. The site of recurrence was delineated on mpMR images and contours transferred on planning CT images using both rigid and deformable registrations. Coregistrations were evaluated by mathematical operators that quantify deformation (Jacobian determinant and vector curl) and similarity indices (Dice and Jaccard coefficients). Dose coverage was evaluated.

Results: Deformable registration did not change volumes, (p = 0.92 MW test). The Jacobian coefficient and the vector curl revealed no important image deformations. Dice and Jaccard coefficients indicated dislocation of the nodule volumes. Dislocation magnitude was d = (5.6 ± 3.1) mm. Organ filling was not correlated with deformation or dislocation. Volumes were covered by the 95% isodose in 96% of cases when rigid registration was performed versus 75% of cases when deformed.

Conclusions: Rigid image coregistration is sufficiently accurate in this setting. The results indicate that the deformable registration tends to shrink the voxels and to dislocate the ROI, the adopted expansion for the recurrence volume adequately accounts for the observed deformation and dislocation, provided that organ filling is controlled.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2021.11.010DOI Listing

Publication Analysis

Top Keywords

organ filling
12
rigid deformable
8
images radiotherapy
8
radiotherapy prostate
8
prostate bed
8
bed cancer
8
vector curl
8
dice jaccard
8
jaccard coefficients
8
deformable registration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!