Purpose: The retinal circulation regulates blood flow through various internal and external factors; however, it is unclear how locally these factors act within the retinal microcirculation. We measured the temporal and spatial variability of blood velocity in small retinal vessels using a dual-beam adaptive optics scanning laser ophthalmoscope.

Methods: In young healthy subjects (n = 3), temporal blood velocity variability was measured in a local vascular region consisting of an arteriole, capillary, and venule repeatedly over 2 days. Data consisted of 10 imaging periods separated into two sessions: (1) five 6-minute image acquisition periods with 30-minute breaks, and (2) five 6-minute image acquisition periods with 10-minute breaks. In another group of young healthy subjects (n = 5), spatial distribution of velocity variability was measured by imaging three capillary segments during three 2-minute conditions: (1) baseline imaging condition (no flicker), (2) full-field flicker, and (3) no flicker condition again.

Results: Blood velocities were measurable in all subjects with a reliability of about 2%. The coefficient of variation (CV) was used as an estimate of the physiological variability of each vessel. Over 2 days, the average CV in arterioles was 7% (±2%); in capillaries, it was 19% (±6%); and, in venules, it was 8% (±2%). During flicker stimulation, the average capillary CV was 16% during baseline, 15% during flicker stimulation, and 18% after flicker stimulation.

Conclusions: Capillaries in the human retina exhibit spatial and temporal variations in blood velocity. This inherent variation in blood velocity places limits on studying the vascular regulation of individual capillaries, and the study presented here serves as a foundation for future endeavors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8648047PMC
http://dx.doi.org/10.1167/iovs.62.14.29DOI Listing

Publication Analysis

Top Keywords

blood velocity
16
temporal spatial
8
spatial variability
8
retinal vessels
8
young healthy
8
healthy subjects
8
velocity variability
8
variability measured
8
6-minute image
8
image acquisition
8

Similar Publications

Background: The development of heat transfer devices used for heat conversion and recovery in several industrial and residential applications has long focused on improving heat transfer between two parallel plates. Numerous articles have examined the relevance of enhancing thermal performance for the system's performance and economics. Heat transport is improved by increasing the Reynolds number as the turbulent effects grow.

View Article and Find Full Text PDF

To measure the influence of ganglion cell layer (GCL) thickness on the changes in size and red blood cell (RBC) flow in small retinal vessels evoked by full-field flicker. We used a dual-beam adaptive optics scanning laser ophthalmoscope to image 11 healthy young controls in two retinal areas with significantly different GCL thicknesses. All capillaries and arterioles of the superficial vascular plexus were responsive to the flicker stimulation.

View Article and Find Full Text PDF

Objective: Globally, one in four pregnant women is classified as overweight or obese, based on their prepregnancy body mass index (BMI). Obese pregnant women are at increased risk of adverse pregnancy outcomes and long-term cardiovascular disease that occurs earlier in life. This study aimed to assess maternal hemodynamic and vascular parameters at 35-37 weeks' gestation, to understand the alterations that may occur in association with increased maternal BMI and gestational weight gain, and to evaluate obesity-related pregnancy outcomes.

View Article and Find Full Text PDF

Objective: The present study aims to investigate potential differences in cerebral blood flow between children with Cognitive Disengagement Syndrome (CDS) and those with Attention Deficit Hyperactivity Disorder (ADHD) using Doppler ultrasound.

Methods: In this single-center prospective study, we included 24 cases in the ADHD group with CDS symptoms, 29 cases in the ADHD group without CDS symptoms and, 26 children in the healthy controls. The children ranged in age from 6 to 15.

View Article and Find Full Text PDF

The compliant nature of cerebral blood vessels may represent an important mechanical protection for sustained cerebral perfusion during reductions in arterial blood pressure (ABP). However, whether the rise in cerebrovascular compliance (Ci) with falling ABP persists and exhibits a threshold effect remains unknown. Therefore, we analyzed Ci changes during graded head-up tilt (HUT) in individuals with autonomic failure (AF), a group that tolerates graded and progressive reductions in ABP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!