Introduction: Transcatheter aortic valve‑in ‑valve implantation (ViV‑TAVI) has emerged as an alternative to redo surgery in patients with failed surgical aortic bioprosthesis.

Objectives: We evaluated the safety and efficacy of ViV‑TAVI in Polish patients after surgical aortic valve replacement.

Patients And Methods: This was a nationwide multicenter registry of ViV‑TAVI procedures. Data were collected using an online form, and the clinical follow ‑up lasted 1 year.

Results: From 2008 to 2020, 130 ViV‑TAVI procedures were performed (1.9% of all transcatheter aortic valve implantation [TAVI] cases). A considerable increase in ViV‑TAVI procedures since 2018 has been observed (n = 59, 45% of ViV‑TAVI cases). Hancock II, Freestyle, and homograft were the most frequently treated bioprostheses. The self ‑expanding supra ‑annular Corevalve / Evolut valve was used in 76% of cases. In 21% of cases, the mean postprocedural pressure gradient (PG) exceeded 20 mm Hg. All‑cause mortal‑ity at 1 year was 10.8%. Aortic valve stenosis was associated with a higher mean PG than aortic valve regurgitation or mixed disease (P = 0.004). Supra ‑annular transcatheter aortic valves were associated with lower mean PGs than intra ‑annular valves (P = 0.004). Second ‑generation devices were associated with shorter procedure time (120 min vs 135 min, P = 0.04), less frequent need for additional TAVI (2% vs 10%, P = 0.04), and lower 1‑year cardiovascular mortality (95% vs 82.8%, P = 0.03) than first‑generation valves.

Conclusions: Transcatheter treatment of failed bioprostheses is increasingly common, with the best hemodynamic effect shown for supra ‑annular valves. The introduction of second‑generation valves has improved procedural and clinical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.20452/pamw.16149DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
20
aortic valve
16
viv‑tavi procedures
12
supra ‑annular
12
failed surgical
8
aortic
8
implantation viv‑tavi
8
surgical aortic
8
‑annular valves
8
viv‑tavi
7

Similar Publications

Since the first transcatheter aortic valve replacement (TAVR) was performed in China in 2010, TAVR has developed rapidly. However, the temporal trends in the 1-year prognosis after TAVR in China have not been described. This study enrolled patients treated at a high-volume Chinese TAVR center, West China Hospital, between 2015 and 2022, to analyze and characterize the temporal trends in 1-year outcomes.

View Article and Find Full Text PDF

In the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) era, implanting a larger-sized valve during the initial aortic valve replacement is important. For smaller aortic annuli, combining aortic annular and left ventricular outflow tract (LVOT) enlargement is essential. The Y-incision procedure helps achieve implantation of a 2-size larger valve.

View Article and Find Full Text PDF

Transcatheter Bailout: An Important Option During Complex Aortic Surgery.

Ann Thorac Surg Short Rep

December 2024

Division of Adult Cardiothoracic Surgery, Department of Surgery, University of California, San Francisco, San Francisco, California.

This report presents the case of a 66-year-old man with acute torrential aortic insufficiency after a Ross procedure 20 years earlier, a biologic aortic valve replacement 16 years earlier, and a transcatheter valve-in-valve 4 years earlier. He underwent third-time sternotomy, revealing that the pulmonary autograft was heavily calcified and frozen to the homograft. The previous transcatheter valve-in-valve was explanted.

View Article and Find Full Text PDF

We report a case of a woman who underwent mitral ring and tricuspid annuloplasty. Two months later, she presented with acute heart failure secondary to severe aortic regurgitation, which was a complication of the cardiac surgery. Given the high surgical risk of reoperation in this the patient, she underwent transcatheter aortic valve implantation, with a good result.

View Article and Find Full Text PDF

A 90-year-old man received a diagnosis of ascending aortic pseudoaneurysms after transcatheter aortic valve implantation (TAVI) using an Evolut PRO valve (Medtronic). Plug closure of the pseudoaneurysms was successfully performed, and the symptoms improved after the procedure. However, on postoperative day 4, the patient experienced sudden massive hemoptysis and died.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!