Background: The purpose of this study was to assess the accuracy of intraocular lens power (IOL) formulas for cataract surgery after deep anterior lamellar keratoplasty (DALK).

Methods: This retrospective study included eyes which had previously undergone DALK and underwent standard phacoemulsification with monofocal IOL implantation between January 2012 and January 2021 at Ospedali Privati Forlì "Villa Igea" (Forlì, Italy). The predicted spherical equivalent (SE) was calculated using the Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Hoffer Q, Hoffer QST, Holladay 1, Holladay II, Kane and SRK/T formulas. Prediction error (PE) was calculated as the actual postoperative SE refraction minus the SE predicted refraction.

Results: Eighty-two eyes of 82 patients were included. The mean PE was negative using all formulas. Friedman test revealed a statistically significant difference of the median absolute PE (MedAE) among the different IOL formulas (P = 0.005). On the basis of the MedAE, the formulas were ranked as follows: SRK/T (0.805 D), Kane (0.810 D), EVO (0.845 D), Hoffer QST (0.847 D), Barrett (0.895 D), Holladay 1 (0.915 D), Haigis (1.010 D) and Hoffer Q (1.070 D) formulas.

Conclusions: All formulas had a tendency towards a myopic refractive shift in post-DALK eyes. Although the SRK/T, Kane, EVO and Hoffer QST formulas were more accurate, predictability of refractive outcomes was lower than in virgin eyes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ceo.14026DOI Listing

Publication Analysis

Top Keywords

hoffer qst
12
accuracy intraocular
8
intraocular lens
8
lens power
8
cataract surgery
8
surgery deep
8
deep anterior
8
anterior lamellar
8
lamellar keratoplasty
8
iol formulas
8

Similar Publications

Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.

Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.

View Article and Find Full Text PDF

Background: The purpose of the study was to evaluate the relationship between prediction errors (PEs) and ocular biometric variables in cataract surgery using nine intraocular lens (IOL) formulas with an explainable machine learning model.

Methods: We retrospectively analyzed the medical records of consecutive patients who underwent standard cataract surgery with a Tecnis 1-piece IOL (ZCB00) at a single center. We calculated predicted refraction using the following IOL formulas: Barrett Universal II (BUII), Cooke K6, EVO V2.

View Article and Find Full Text PDF

Accuracy of 7 Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Extremely Long Caucasian Eyes.

Am J Ophthalmol

November 2024

Institute for Research in Ophthalmology (A.G.), Foundation for Ophthalmology Development, Poznan, Poland; Department of Ophthalmology (A.G.), University of Warmia and Mazury, Olsztyn, Poland. Electronic address:

Purpose: To compare 7 artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in extremely long eyes.

Design: Retrospective accuracy and validity analysis.

Setting: Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Ukraine.

View Article and Find Full Text PDF

This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.

View Article and Find Full Text PDF

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas for myopic eyes requiring negative diopter powered IOLs.

Design: Retrospective case series.

Setting: K… hospital and Y… Hospital, …, ….

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!