Improvement of magnetic resonance imaging using a wireless radiofrequency resonator array.

Sci Rep

BioMedical Engineering and Imaging Institute and Friedman Brain Institute, Icahn School of Medicine at Mount Sinai, 1470 Madison Ave., 1st Floor, New York, NY, 10029, USA.

Published: November 2021

In recent years, new human magnetic resonance imaging systems operating at static magnetic fields strengths of 7 Tesla or higher have become available, providing better signal sensitivity compared with lower field strengths. However, imaging human-sized objects at such high field strength and associated precession frequencies is limited due to the technical challenges associated with the wavelength effect, which substantially disturb the transmit field uniformity over the human body when conventional coils are used. Here we report a novel passive inductively-coupled radiofrequency resonator array design with a simple structure that works in conjunction with conventional coils and requires only to be tuned to the scanner's operating frequency. We show that inductive-coupling between the resonator array and the coil improves the transmit efficiency and signal sensitivity in the targeted region. The simple structure, flexibility, and cost-efficiency make the proposed array design an attractive approach for altering the transmit field distribution specially at high field systems, where the wavelength is comparable with the tissue size.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8630230PMC
http://dx.doi.org/10.1038/s41598-021-02533-3DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
8
resonance imaging
8
signal sensitivity
8
high field
8
transmit field
8
conventional coils
8
resonator array
8
array design
8
simple structure
8
field
5

Similar Publications

Magnetic resonance imaging (MRI) is frequently used to monitor disease progression in multiple sclerosis (MS). This study aims to systematically evaluate the correlation between MRI measures and histopathological changes, including demyelination, axonal loss, and gliosis, in the central nervous system of MS patients. We systematically reviewed post-mortem histological studies evaluating myelin density, axonal loss, and gliosis using quantitative imaging in MS.

View Article and Find Full Text PDF

Increased intolerance of uncertainty (IU), or distress felt when encountering situations with unknown outcomes, occurs transdiagnostically across various forms of psychopathology and is targeted in therapeutic intervention. Increased intolerance of uncertainty shows overlap with symptoms of internalizing disorders, such as depression and anxiety, including negative affect and anxious apprehension (worry). While neuroanatomical correlates of IU have been reported, previous investigations have not disentangled the specific neural substrates of IU above and beyond any overlapping relationships with aspects of internalizing psychopathology.

View Article and Find Full Text PDF

The use of conventional contrast agents in computed tomography (CT) and magnetic resonance (MR) imaging is often limited in patients with chronic kidney disease (CKD) due to potential nephrotoxicity. Ferumoxytol, originally developed for iron supplementation, has emerged as a promising alternative MR contrast agent that is safer for patients with CKD. This study aims to present our center's experience with ferumoxytol as a contrast agent in CKD patients.

View Article and Find Full Text PDF

Purpose: To comprehensively compare the diagnostic ability and inter-reader agreement of magnetic resonance imaging (MRI) findings for predicting massive hemorrhage after cesarean section in patients with placental malposition, aiming to identify the most reliable and objective indicators.

Methods: Totally, 148 consecutive patients with placental malposition underwent MRI and cesarean section at our hospital between January 2014 and July 2021. The patients were divided into massive and non-massive hemorrhage groups.

View Article and Find Full Text PDF

Objective: Total hip arthroplasty through the Hardinge approach damages the hip abductor muscles. MRI can be used to assess adverse postoperative events. In this prospective randomized controlled trial, we evaluated MRI findings and whether platelet-rich plasma affected postoperative healing of the gluteal muscles (gluteus medius and minimus).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!