Background: Hearing loss is an important disorder affecting newborns admitted to NICU. A national hearing screening program using otoacoustic emission testing is an essential tool to identify hearing loss early in neonates, enabling early intervention to avoid further challenges of pediatric deafness. On the other hand, a delay of the auditory pathway maturation in preterm babies compared to term newborns has already been suggested in the literature. Taking this information into account, in this paper, we aim to identify the best time to perform NICU infant hearing screening tests.

Objectives: We aim to study the clinical factors and neonatal morbidities that may affect neonatal hearing screening results using otoacoustic emission test in order to decrease the false-positive test results that increase parental anxiety and increase the need for subsequent investigations.

Methods: This is a prospective cross-sectional study that included 204 infants who were admitted to a tertiary referral hospital NICU unit between September 2017 and May 2018. Both transients evoked otoacoustic emissions (TEOAE), and distortion product otoacoustic emission (DPOAE) screening tests were performed in order to screen hearing loss.

Results: Our study included 204 infants, 52.9 % of which were males and 47.1 % females. There were correlations between both hyperbilirubinemia and ventilation ≥ 5 days and the failure rate of the first OAE test results among NICU infants where the P-values were (p=0.0133) and (p=0.0456), respectively. Moreover, 165 babies (80.9 %) passed the first OAE with a mean birth weight of 2759 gram and mean maternal age of 30.6 years, while 39 babies (19.1 %) failed the test with a mean birth weight of 2436 gram and a mean maternal age of 32 years. There was no statistically significant relation between both maternal age and birth weight with failure of the first screening test.

Conclusion: Our study suggests a higher failure rate of the first OAE in NICU infants who had hyperbilirubinemia or ventilation ≥ 5 days. Therefore, our recommendation is to postpone the first phase of hearing screening for those infants until the first scheduled vaccine appointment to achieve high compliance to attendance and decrease distress to the family that can be associated with false-negative results of the test.

Download full-text PDF

Source
http://dx.doi.org/10.2174/1573396317666211129092341DOI Listing

Publication Analysis

Top Keywords

hearing screening
20
otoacoustic emission
12
birth weight
12
maternal age
12
clinical factors
8
factors neonatal
8
neonatal morbidities
8
hearing
8
hearing loss
8
study included
8

Similar Publications

Background: Age-related macular degeneration (AMD) is a prevalent cause of irreversible vision loss among the elderly. The prevalence and detailed characteristics of Charles Bonnet syndrome (CBS) remain largely unexplored in patients with geographic atrophy (GA) secondary to AMD.

Objectives: To investigate the prevalence and characteristics of CBS in patients with GA secondary to AMD.

View Article and Find Full Text PDF

Jansen metaphyseal chondrodysplasia (JMC) is an ultra-rare disorder caused by constitutive activation of parathyroid hormone type 1 receptor (PTH1R). We sought to characterize the craniofacial phenotype of patients with the disease. Six patients with genetically confirmed JMC underwent comprehensive craniofacial phenotyping revealing a distinct facial appearance that prompted a cephalometric analysis demonstrating a pattern of mandibular retrognathia.

View Article and Find Full Text PDF

We present a case of a male in his early 50s assessed in the emergency department with a seemingly clear alcohol history but with classic symptoms of Wernicke's encephalopathy (WE): disorientation, gait ataxia and vertical nystagmus. He also had significant bilateral hearing loss and profound anterograde amnesia. Neuroimaging revealed hallmark signs of WE, including symmetrical T2/fluid-attenuated inversion recovery hyperintensity in the medial thalami.

View Article and Find Full Text PDF

Background: There is conflicting literature regarding whether cochlear implants (CI) electrode array (EA) selection impacts audiologic outcomes.

Objective: To compare outcomes for the two EA designs, precurved and straight.

Methods: A systematic search of CINAHL, Cochrane Library, PubMed, and SCOPUS was conducted according to PRISMA guidelines.

View Article and Find Full Text PDF

Spontaneous otoacoustic emission as a novel method to screen pulsatile tinnitus caused by sigmoid sinus wall abnormalities: a prospective study.

Eur Arch Otorhinolaryngol

January 2025

ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.

Objective: To evaluate the diagnostic potential of spontaneous otoacoustic emissions (SOAE), distortion product otoacoustic emissions (DPOAE), and pure-tone audiometry (PTA) in patients with pulsatile tinnitus (PT) caused by sigmoid sinus wall anomalies (SSWA).

Methods: This study included 20 PT patients and 20 matched healthy controls. SOAE, DPOAE, and PTA were assessed before and after compression of the internal jugular vein.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!