A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Harnessing Digital Health to Objectively Assess Functional Performance in Veterans with Chronic Obstructive Pulmonary Disease. | LitMetric

Introduction: An early detection of impaired functional performance is critical to enhance symptom management for patients with chronic obstructive pulmonary disease (COPD). However, conventional functional measures based on walking assessments are often impractical for small clinics where the available space to administrate gait-based test is limited. This study examined the feasibility and effectiveness of an upper-extremity frailty meter (FM) in identifying digital measures of functional performance and assessing frailty in COPD patients.

Methods: Forty-eight patients with COPD (age = 68.8 ± 8.5 years, body mass index [BMI] = 28.7 ± 5.8 kg/m2) and 49 controls (age = 70.0 ± 3.0 years, BMI = 28.7 ± 6.1 kg/m2) were recruited. All participants performed a 20-s repetitive elbow flexion-extension test using a wrist-worn FM sensor. Functional performance was quantified by FM metrics, including speed (slowness), range of motion (rigidity), power (weakness), flexion and extension time (slowness), as well as speed and power reduction (exhaustion). Conventional functional measures, including timed-up-and-go test, gait and balance tests, and 5 repetition sit-to-stand test, were also performed.

Results: Compared to controls, COPD patients exhibited deteriorated performances in all conventional functional assessments (d = 0.64-1.26, p < 0.010) and all FM metrics (d = 0.45-1.54, p < 0.050). FM metrics had significant agreements with conventional assessment tools (|r| = 0.35-0.55, p ≤ 0.001). FM metrics efficiently identified COPD patients with pre-frailty and frailty (d = 0.82-2.12, p < 0.050).

Conclusion: This study proposes the feasibility of using a 20-s repetitive elbow flexion-extension test and wrist-worn sensor-derived frailty metrics as an alternative and practical solution to evaluate functional performance in COPD patients. Its simplicity and low risk for test administration may also facilitate its application for remote patient monitoring. Furthermore, in settings where the administration of walking test is impractical, for example, when ventilator support is needed or space is limited, FM may be used as an alternative solution. Future studies are encouraged to use the FM to quantitatively monitor the progressive decline in functional performance and quantify outcomes of rehabilitation interventions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9148378PMC
http://dx.doi.org/10.1159/000520401DOI Listing

Publication Analysis

Top Keywords

functional performance
24
conventional functional
12
copd patients
12
functional
9
chronic obstructive
8
obstructive pulmonary
8
pulmonary disease
8
functional measures
8
287 kg/m2
8
20-s repetitive
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!