His bundle pacing (HBP) is proven to be a safe and effective alternative pacing modality that, in addition, avoids pacemaker-induced cardiomyopathy (PICM) by achieving a "physiological" ventricular stimulation, via the native conduction system. Indications include various causes of bradycardia requiring anti-bradycardic pacing, inadequately controlled atrial fibrillation requiring AV node ablation and established PICM. In addition, HBP may also be used as an alternative therapy for patients with heart failure (HF) and an indication for cardiac resynchronization therapy (CRT). Available data show several advantages of HBP with regard to preservation or restoration of intra- and inter-ventricular synchronization; improvement in left ventricular ejection fraction, functional status and quality of life; decrease in atrial fibrillation incidence and improvement in HF hospitalization rates, compared with conventional pacing. Nevertheless, superiority in terms of mortality rates has not been consistently demonstrated, and the long-term efficacy and safety of HBP remain to be proven. In the present manuscript, we review the status of HBP and present our current experience with this novel pacing modality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hjc.2021.10.005 | DOI Listing |
J Cardiovasc Electrophysiol
January 2025
Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.
Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.
Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.
J Interv Card Electrophysiol
January 2025
Department of Cardiology, Immacolata Concezione Hospital, Via S. Rocco 8, 35028, Piove Di Sacco (PD), Italy.
JACC Clin Electrophysiol
January 2025
Cardiac Pacing Unit, Department of Cardiology, University Hospital of Geneva, Geneva, Switzerland. Electronic address:
Front Cardiovasc Med
January 2025
Department of Cardiology, The First People's Hospital of Neijiang, Neijiang, China.
More than 1 million permanent pacemakers are implanted worldwide each year, half of which are in patients with high-grade atrioventricular block. Pacemakers provide adequate frequency support in the initial stage, but traditional right ventricular (RV) pacing may lead to or aggravate left ventricular dysfunction and arrhythmia. Several potential risk factors for heart failure and arrhythmias after pacemaker surgery have been identified, but their occurrence remains difficult to predict clinically.
View Article and Find Full Text PDFJACC Case Rep
December 2024
Department of Cardiology, Northern Beaches Hospital, Frenchs Forest, Australia.
A 72-year-old woman underwent left bundle branch area pacing, and subsequent transthoracic echocardiography demonstrated potential septal lead perforation. Transesophageal echocardiography revealed an intracardiac mass, which resolved with anticoagulation. This case highlights left ventricular thrombus as a potential complication of septal lead perforation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!