His bundle pacing (HBP) is proven to be a safe and effective alternative pacing modality that, in addition, avoids pacemaker-induced cardiomyopathy (PICM) by achieving a "physiological" ventricular stimulation, via the native conduction system. Indications include various causes of bradycardia requiring anti-bradycardic pacing, inadequately controlled atrial fibrillation requiring AV node ablation and established PICM. In addition, HBP may also be used as an alternative therapy for patients with heart failure (HF) and an indication for cardiac resynchronization therapy (CRT). Available data show several advantages of HBP with regard to preservation or restoration of intra- and inter-ventricular synchronization; improvement in left ventricular ejection fraction, functional status and quality of life; decrease in atrial fibrillation incidence and improvement in HF hospitalization rates, compared with conventional pacing. Nevertheless, superiority in terms of mortality rates has not been consistently demonstrated, and the long-term efficacy and safety of HBP remain to be proven. In the present manuscript, we review the status of HBP and present our current experience with this novel pacing modality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hjc.2021.10.005DOI Listing

Publication Analysis

Top Keywords

bundle pacing
8
anti-bradycardic pacing
8
pacing modality
8
atrial fibrillation
8
pacing
6
hbp
5
pacing promising
4
promising alternative
4
alternative strategy
4
strategy anti-bradycardic
4

Similar Publications

Permanent Left Bundle Branch Area DF-4 Defibrillator Lead Implantation-Feasibility, Procedural Caveats, Safety, and Follow-Up.

J Cardiovasc Electrophysiol

January 2025

Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.

Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.

Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.

View Article and Find Full Text PDF

More than 1 million permanent pacemakers are implanted worldwide each year, half of which are in patients with high-grade atrioventricular block. Pacemakers provide adequate frequency support in the initial stage, but traditional right ventricular (RV) pacing may lead to or aggravate left ventricular dysfunction and arrhythmia. Several potential risk factors for heart failure and arrhythmias after pacemaker surgery have been identified, but their occurrence remains difficult to predict clinically.

View Article and Find Full Text PDF

A 72-year-old woman underwent left bundle branch area pacing, and subsequent transthoracic echocardiography demonstrated potential septal lead perforation. Transesophageal echocardiography revealed an intracardiac mass, which resolved with anticoagulation. This case highlights left ventricular thrombus as a potential complication of septal lead perforation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!