Comparison of Microflow and Analytical Flow Liquid Chromatography Coupled to Mass Spectrometry Global Metabolomics Methods Using a Urea Cycle Disorder Mouse Model.

J Proteome Res

Barnett Institute of Chemical and Biological Analysis, Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts 02115, United States.

Published: January 2022

Microscale-based separations are increasingly being applied in the field of metabolomics for the analysis of small-molecule metabolites. These methods have the potential to provide improved sensitivity, less solvent waste, and reduced sample-size requirements. Ion-pair free microflow-based global metabolomics methods, which we recently reported, were further compared to analytical flow ion-pairing reagent containing methods using a sample set from a urea cycle disorder (UCD) mouse model. Mouse urine and brain homogenate samples representing healthy, diseased, and disease-treated animals were analyzed by both methods. Data processing was performed using univariate and multivariate techniques followed by analyte trend analysis. The microflow methods performed comparably to the analytical flow ion-pairing methods with the ability to separate the three sample groups when analyzed by partial least-squares analysis. The number of detected metabolic features present after each data processing step was similar between the microflow-based methods and the ion-pairing methods in the negative ionization mode. The observed analyte trend and coverage of known UCD biomarkers were the same for both evaluated approaches. The 12.5-fold reduction in sample injection volume required for the microflow-based separations highlights the potential of this method to support studies with sample-size limitations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8742624PMC
http://dx.doi.org/10.1021/acs.jproteome.1c00628DOI Listing

Publication Analysis

Top Keywords

analytical flow
12
methods
9
global metabolomics
8
metabolomics methods
8
urea cycle
8
cycle disorder
8
mouse model
8
flow ion-pairing
8
data processing
8
analyte trend
8

Similar Publications

More Than a Haematoma: A Case of Aplastic Anemia.

Cureus

December 2024

Family Medicine, Family Health Unit (USF) Almedina, Local Health Unit of Trás-os-Montes and Alto Douro (ULSTMAD), Lamego, PRT.

Easy bruising and ecchymosis are common symptoms in clinical practice, yet distinguishing benign from clinically significant cases can be challenging. We report the case of a 46-year-old woman who presented in December 2023 with easy bruising and increased menstrual flow, revealing new-onset pancytopenia in laboratory tests. Initially diagnosed with Acute Myeloid Leukemia inversion (inv) (16), subsequent results were inconclusive, leading to a diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH).

View Article and Find Full Text PDF

A simple, rapid, and reproducible high-performance liquid chromatography (HPLC) method has been developed and validated for the determination of β-sitosterol in the pharmaceutical dosage form of moist exposed burn ointment (MEBO). This method involved an effective sample procedure for extraction of β-sitosterol from MEBO using an alkali saponification agent composed of 0.8 N ethanolic NaOH and diethyl ether.

View Article and Find Full Text PDF

Lateral flow assay with automatic signal amplification based on delayed substrate release.

Talanta

January 2025

State Key Laboratory of Food Science and Resources, Jiangnan University, Lihu Road 1800, Wuxi, 214122, PR China; School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi, 214122, PR China; International Joint Laboratory on Food Safety, Jiangnan University, Lihu Road 1800, Wuxi, 214122, PR China.

The low sensitivity of Lateral flow assay (LFA) limits its application in rapid detection for trace targets. LFAs with nanozyme (nanozyme-LFA) as signal labels have demonstrated excellent performance in point of care testing (POCT). However, additional operational steps for substrate catalysis in nanozyme LFA are required, which makes the nanozyme-LFA operation complicated.

View Article and Find Full Text PDF

In this study, a new reversed phase high performance liquid chromatography method using two detectors was developed for the analysis of degradation and process impurities of ivabradine in pharmaceutical preparations. A PDA detector set to 285 nm wavelength and a QDa detector set to positive scan mode were used in the method. In the developed method, the separation process was carried out in a Zorbax phenyl column with a gradient application of a 0.

View Article and Find Full Text PDF

Plasmids play a vital role in synthetic biology by enabling the introduction and expression of foreign genes in various organisms, thereby facilitating the construction of biological circuits and pathways within and between cell populations. For many applications, maintaining functional plasmids without antibiotic selection is critical. This study introduces an open-hardware-based microfluidic workflow for analyzing plasmid retention by culturing single cells in gel microdroplets and quantifying microcolonies using fluorescence microscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!