[Comparison of the efficacy of different venous intubation in venous-arterial extracorporeal membrane oxygenation assisted lung transplantation].

Zhonghua Wei Zhong Bing Ji Jiu Yi Xue

Department of Cardiac Surgery, People's Hospital of Henan Province, People's Hospital of Zhengzhou University, Fuwai Central China Cardiovascular Disease Hospital, Zhengzhou 450000, Henan, China. Corresponding author: Cheng Zhaoyun, Email:

Published: September 2021

Objective: To compare the curative effects of different venous cannulas and drainage to improve patient's whole body oxygenation during the auxiliary process of venous-arterial extracorporeal membrane oxygenation (VA-ECMO) in lung transplantation.

Methods: From December 2016 to December 2019, 12 patients who were assisted by VA-ECMO in one lung transplantation in People's Hospital of Henan Province were selected as the research objects. According to the number of side holes of venous cannulas, they were divided into two groups: one group with few side holes and other group with multiple side holes. The differences in blood gas indexes among the right radial artery, left radial artery, and right internal jugular vein before and after assistance were compared, and the assistance effect was evaluated.

Results: The arterial partial pressure of oxygen (PaO) of blood gas indexes of the right and left radial arteries in both groups were significantly higher than that before assistance [mmHg (1 mmHg = 0.133 kPa): right and left radial artery in few side holes group: 79.5±4.2 vs. 48.3±3.8 and 88.1±3.5 vs. 48.3±3.8; right and left radial artery in multiple side holes group: 67.7±5.9 vs. 48.7±3.2 and 84.0±3.8 vs. 48.7±3.2, all P < 0.05]. The arterial partial pressure of carbon dioxide (PaCO) of blood gas index was significantly lower than that before assistance (mmHg: 44.2±2.6 vs. 71.7±4.4 for the right radial artery and 44.7±1.4 vs. 71.7±4.4 for the left radial artery in the group with few side holes; 46.2±2.1 vs. 71.2±3.5 for the right radial artery and 44.1±1.9 vs. 71.2±3.5 for the left radial artery in the group with multiple side holes, all P < 0.05). The partial pressure of oxygen in venous blood (PvO) of blood gas index of ECMO system in the group with few side holes was significantly lower than that of the multiport side holes group (mmHg: 56.4±3.2 vs. 88.7±1.5, P < 0.01), and the partial pressure of carbon dioxide in venous blood (PvCO) was significantly higher than that of multiport side holes group (mmHg: 63.6±3.7 vs. 44.2±1.7, P < 0.01).

Conclusions: When VA-ECMO is used in lung transplantation, the superior vena cava blood flow can be fully drained by using intravenous cannula with few side holes. It can effectively improve the oxygenation of the upper body of lung transplant patients, avoid the dilemma of hypoxemia in the upper body and hyperxemia in the lower body, provide more effective assistance to patients undergoing single lung transplantation, and is more meaningful for improving the oxygenation status of the whole body in patients undergoing single lung transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn121430-20210104-00003DOI Listing

Publication Analysis

Top Keywords

side holes
44
radial artery
32
left radial
24
holes group
20
lung transplantation
16
blood gas
16
partial pressure
16
va-ecmo lung
12
group side
12
multiple side
12

Similar Publications

Dynamic Accommodation Responses in Subjects Wearing Myopia Control Spectacles Modifying Peripheral Refraction.

Invest Ophthalmol Vis Sci

January 2025

Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain.

Purpose: Peripheral optics have been suggested to play a role in myopia progression, with accommodation responses also considered a potential contributor. This study aimed to investigate whether modifications in peripheral optics through different spectacle lenses affect accommodation responses.

Methods: Dynamic accommodation responses were assessed using a double-pass instrument while switching the target from distance (3 m for 3 seconds) to near (0.

View Article and Find Full Text PDF

The effect of the guide hole height on the accuracy of implant placement: An in-vitro study.

J Stomatol Oral Maxillofac Surg

January 2025

School of Dentistry, Chonnam National University, Gwangju, Republic of Korea; Department of Oral & Maxillofacial Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea. Electronic address:

Objective: Guided implant surgery using three-dimensional (3-D) planning software and 3-D printed surgical guides has become a critical tool for enhancing accuracy. This study aims to determine the minimum guide hole height necessary to maintain implant placement accuracy.

Materials And Methods: Ten maxillary models with edentulous areas were created using CT and optical scan data.

View Article and Find Full Text PDF

Compact and Wide-Stopband Bandpass Filter Using Hybrid Shielded EMCSIW and CSRR Resonators with a Mixed Electromagnetic Coupling Scheme.

Micromachines (Basel)

November 2024

State Key Laboratory of Millimeter-Waves, School of Information Science and Engineering, Southeast University, Nanjing 210096, China.

This paper presents a bandpass filter (BPF) exploiting hybrid shielded eighth-mode circular substrate-integrated waveguide (SD-EMCSIW) and complementary split ring resonator (CSRR) resonators. The proposed BPF leverages the SD-EMCSIW resonator with a 45-degree angle to create a second-order BPF with a mixed electromagnetic coupling scheme. Detailed analyses of the related electromagnetic characteristics and operating mechanisms have been performed.

View Article and Find Full Text PDF

Difficult-to-cut titanium matrix composites (TMCs) are widely used in the aerospace, automotive, and defense sectors due to their excellent physical properties. Electrochemical mill grinding (ECMG) can achieve the processing effects of electrochemical milling and electrochemical grinding using the same tool, which has the potential to complete the rough and finish machining of TMCs in succession. However, in the rough machining stage, the bottom of the slot becomes concave due to the inevitable stray corrosion, leading to poor flatness, which increases the machining allowance for subsequent finish machining.

View Article and Find Full Text PDF

Innovative Mechanical Processing of Adipose Tissue: A Comparative Evaluation of Microfat and Concentrated Micronized Fat for Superficial Fat Grafting.

Aesthetic Plast Surg

January 2025

Department of Body Contouring and Fat grafting Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No 33 Badachu Road, Shijingshan District, 100144, Beijing, People's Republic of China.

Background: Superficial autologous fat grafting is widely used for facial rejuvenation and regenerative treatments, yet its retention rate remains unpredictable. Enhancing the concentration of adipose-derived stem cells (ASCs) has been shown to improve graft retention. Mechanical fat processing techniques can reduce fat granules size for superficial injection as well as elevate the concentration of ASCs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!