Accurate profiling of forensic autosomal STRs using the Oxford Nanopore Technologies MinION device.

Forensic Sci Int Genet

Department of Microbiology, Immunology & Genetics, University of North Texas Health Science Center, 3400 Camp Bowie Blvd, Fort Worth, TX 76107, USA; Department of Criminology and Criminal Justice, University of Texas at Arlington, 701 S Nedderman Dr, Arlington, TX 76109, USA.

Published: January 2022

The high variability characteristic of short tandem repeat (STR) markers is harnessed for human identification in forensic genetic analyses. Despite the power and reliability of current typing techniques, sequence-level information both within and around STRs are masked in the length-based profiles generated. Forensic STR typing using next generation sequencing (NGS) has therefore gained attention as an alternative to traditional capillary electrophoresis (CE) approaches. In this proof-of-principle study, we evaluate the forensic applicability of the newest and smallest NGS platform available - the Oxford Nanopore Technologies (ONT) MinION device. Although nanopore sequencing on the handheld MinION offers numerous advantages, including low startup cost and on-site sample processing, the relatively high error rate and lack of forensic-specific analysis software has prevented accurate profiling across STR panels in previous studies. Here we present STRspy, a streamlined method capable of producing length- and sequence-based STR allele designations from noisy, error-prone third generation sequencing reads. To assess the capabilities of STRspy, seven reference samples (female: n = 2; male: n = 5) were amplified at 15 and 30 PCR cycles using the Promega PowerSeq 46GY System and sequenced on the ONT MinION device in triplicate. Basecalled reads were then processed with STRspy using a custom database containing alleles reported in the STRSeq BioProject NIST 1036 dataset. Resultant STR allele designations and flanking region single nucleotide polymorphism (SNP) calls were compared to the manufacturer-validated genotypes for each sample. STRspy generated robust and reliable genotypes across all autosomal STR loci amplified with 30 PCR cycles, achieving 100% concordance based on both length and sequence. Furthermore, we were able to identify flanking region SNPs in the 15-cycle dataset with > 90% accuracy. These results demonstrate that when analyzed with STRspy ONT reads can reveal additional variation in and around STR loci depending on read coverage. As the first and only third generation sequencing platform-specific method to successfully profile the entire panel of autosomal STRs amplified by a commercially available multiplex, STRspy significantly increases the feasibility of nanopore sequencing in forensic applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fsigen.2021.102629DOI Listing

Publication Analysis

Top Keywords

minion device
12
generation sequencing
12
accurate profiling
8
autosomal strs
8
oxford nanopore
8
nanopore technologies
8
ont minion
8
nanopore sequencing
8
str allele
8
allele designations
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!