Smartphone Enabled Point-of-Care Detection of Serum Biomarkers.

Methods Mol Biol

Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC, USA.

Published: January 2022

Sandwich immunoassays are the gold standard for detection of protein analytes. Here, we describe an ultrasensitive point-of-care sandwich immunoassay platform for the detection of biomarkers directly from blood or serum using a custom-built smartphone detector. Testing undiluted blood or serum is challenging due to the complexity of the matrix. Proteins nonspecifically adsorb to and cells often adhere to the assay surface, which can drastically impact the analytical sensitivity of the assay. To address this problem, our assay is built upon a "nonfouling" polymer brush "grafted from" a glass slide, which eliminates nearly all nonspecific binding and therefore increases the signal-to-noise ratio and greatly improves the analytical performance of the test. The two components required to perform a sandwich immunoassay are inkjet-printed directly onto the surface: (1) "stable" capture antibodies that remain entrapped in the brush even after exposure to a liquid sample and (2) fluorescently labeled "soluble" detection antibodies that dissolve upon exposure to a liquid sample. The polymer brush provides hydration to the antibodies, allowing them to remain stable and active over prolonged periods of time. When a liquid sample containing a biomarker of interest is dispensed onto the chip, the detection antibodies dissolve and diffuse to the stable capture spots forming a complex that sandwiches the analyte and that has a fluorescence intensity proportional to the concentration of the biomarker in solution, which can be measured using a custom-built smartphone detector. As multiple capture antibodies can be printed as discrete capture spots, the assay can be easily multiplexed without the need for multiple fluorophores. This chip and detector platform can be utilized for the point-of-care detection of low-abundance biomarkers directly from blood or serum in low-resource settings.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-0716-1803-5_19DOI Listing

Publication Analysis

Top Keywords

blood serum
12
liquid sample
12
point-of-care detection
8
sandwich immunoassay
8
biomarkers directly
8
directly blood
8
custom-built smartphone
8
smartphone detector
8
polymer brush
8
capture antibodies
8

Similar Publications

Efficacy and safety of daprodustat in patients on peritoneal dialysis in the ASCEND-D trial.

Nephrol Dial Transplant

November 2024

Department of Medicine and Nephrology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico.

Background And Hypothesis: Daprodustat, an oral hypoxia-inducible factor prolyl hydroxylase inhibitor, is approved for treatment of anemia in dialysis patients with CKD in some parts of the world. This subgroup analysis examined the efficacy and safety of daprodustat versus darbepoetin alfa in patients with anemia of CKD undergoing peritoneal dialysis (PD).

Methods: ASCEND-D (NCT02879305) was an open-label, Phase 3 trial; patients with CKD were randomized to daprodustat daily and epoetin alfa (HD patients) or darbepoetin alfa (PD patients).

View Article and Find Full Text PDF

Comprehensive review of animal models in diabetes research using chemical agents.

Lab Anim

January 2025

Kastamonu University, Faculty of Medicine, Department of Physiology, Kastamonu, Turkey.

Diabetes mellitus, characterized by insufficient insulin secretion and impaired insulin efficacy, disrupts carbohydrate, protein, and lipid metabolism. The global diabetic population is expected to double by 2025, from 380 million, posing a significant health challenge. Most diabetic individuals fall into the type 1 or type 2 categories, and diabetes adversely affects various organs, such as the kidneys, liver, nervous system, reproductive system, and eyes.

View Article and Find Full Text PDF

Introduction: Chronic Kidney Disease (CKD) is recognized as a major global public health problem. Dialysis is the mainstay of treatment for patients with end-stage renal disease and can prolong survival in patients with CKD. As patient survival increases, the treatment of complications becomes more important.

View Article and Find Full Text PDF

Background: Lenvatinib is an oral tyrosine kinase inhibitor that selectively inhib-its receptors involved in tumor angiogenesis and tumor growth. It is an emerging first-line treatment agent for hepatocellular carcinoma (HCC). However, there is no intravenous ad-ministration of Lenvatinib.

View Article and Find Full Text PDF

Background: Certain micronutrient levels have been associated with the risk of developing TB disease. We explored the possible association of selected at-risk micronutrient levels with the development of Mycobacterium tuberculosis (M.tb) infection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!