The SHFT device is a novel running wearable consisting of two pods connected to your smartphone issuing several running metrics based on accelerometer and gyroscope technology. The purpose of this study was to investigate the reliability and validity of the power output (PO) metric produced by the SHFT device. To assess reliability, 12 men ran on an outdoor track at 10.5 km·h and 12 km·h on two consecutive days. To assess validity, oxygen uptake (VO) and SHFT data from eight men and seven women were collected during incremental submaximal running tests on an indoor treadmill on one to four separate days (34 tests in total). SHFT reliability on the outdoor track was strong with coefficients of variance (CV) of 1.8% and 2.4% for 10.5 and 12 km·h, respectively. We observed a very strong linear relationship between PO and VO (r = 0.54) within subjects, and a very strong linear relationship within each subject within each treadmill test (r = 0.80). We conclude that SHFT provides a reliable running power estimate and that a very strong relationship between SHFT-Power and metabolic rate exists, which places SHFT as one of the leading commercially available running power meters.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8623456 | PMC |
http://dx.doi.org/10.3390/s21227516 | DOI Listing |
Sports Med Open
January 2025
Mechanical Engineering Department, Texas Tech University, Lubbock, TX, USA.
Background: Drafting for drag reduction is a tactic commonly employed by elite athletes of various sports. The strategy has been adopted by Kenyan runner Eliud Kipchoge on numerous marathon events in the past, including the 2018 and 2022 editions of the Berlin marathon (where Kipchoge set two official world records), as well as in two special attempts to break the 2 h mark for the distance, the Nike Breaking2 (2017) and the INEOS 1:59 Challenge (2019), where Kipchoge used an improved drafting formation to finish in 1:59:40, although that is not recognized as an official record.
Results: In this study, the drag of a realistic model of a male runner is calculated by computational fluid dynamics for a range of velocities.
Sci Rep
January 2025
Rocket Force University of Engineering, Xi'an, 710025, P. R. China.
With the increasing intelligence and diversification of communication interference in recent years, communication interference resource scheduling has received more attention. However, the existing interference scenario models have been developed mostly for remote high-power interference with a fixed number of jamming devices without considering power constraints. In addition, there have been fewer scenario models for short-range distributed communication interference with a variable number of jamming devices and power constraints.
View Article and Find Full Text PDFJ Biomech
January 2025
Walker Department of Mechanical Engineering, The University of Texas at Austin Austin TX USA.
Skipping represents a training alternative to running due to its lower knee contact forces and higher whole-body metabolic cost. The increased metabolic cost of skipping is associated with a higher vertical center-of-mass (COM) displacement during the support and flight phases of the skipping hop compared to running. However, skipping has lower muscle force impulses than running.
View Article and Find Full Text PDFChemistryOpen
January 2025
Department of Pharmacy and Health Management, Hebei Chemical & Pharmaceutical College, Shijiazhuang, China.
Self-powered devices for human motion monitoring and energy harvesting have garnered widespread attention in recent research. In this work, we designed a honeycomb-structured triboelectric nanogenerator (H-TENG) using polyester cloth and Teflon tape, with aluminum foil as the conductive electrode. This design leverages the large surface area and flexibility of textiles, resulting in significant performance improvements.
View Article and Find Full Text PDFEur J Sport Sci
February 2025
Department of Physical Education and Sports, Faculty of Sport Sciences, University of Granada, Granada, Spain.
This study aims to determine the validity of the linear critical power (CP) and Peronnet models to estimate the power output associated with the second ventilatory threshold (VT2) and the maximal aerobic power (MAP) using two-time trials. Nineteen recreational runners (10 males and 9 females and maximum oxygen uptake: 53.0 ± 4.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!