Automated Medical Care: Bradycardia Detection and Cardiac Monitoring of Preterm Infants.

Medicina (Kaunas)

Fundamentals of Physics for Engineers Department, "Politehnica" University Timisoara, Bd. Vasile Pârvan 2, 300223 Timisoara, Romania.

Published: November 2021

: Prematurity of birth occurs before the 37th week of gestation and affects up to 10% of births worldwide. It is correlated with critical outcomes; therefore, constant monitoring in neonatal intensive care units or home environments is required. The aim of this work was to develop solutions for remote neonatal intensive supervision systems, which should assist medical diagnosis of premature infants and raise alarm at cardiac abnormalities, such as bradycardia. Additionally, the COVID-19 pandemic has put a worldwide stress upon the medical staff and the management of healthcare units. : A traditional medical diagnosing scheme was set up, implemented with the aid of powerful mathematical operators. The algorithm was tailored to the infants' personal ECG characteristics and was tested on real ECG data from the publicly available PhysioNet database "Preterm Infant Cardio-Respiratory Signals Database". Different processing problems were solved: noise filtering, baseline drift removal, event detection and compression of medical data using the à trous wavelet transform. : In all 10 available clinical cases, the bradycardia events annotated by the physicians were correctly detected using the RR intervals. Compressing the ECG signals for remote transmission, we obtained compression ratios (CR) varying from 1.72 to 7.42, with the median CR value around 3. : We noticed that a significant amount of noise can be added to a signal while monitoring using standard clinical sensors. We tried to offer solutions for these technical problems. Recent studies have shown that persons infected with the COVID-19 disease are frequently reported to develop cardiovascular symptoms and cardiac arrhythmias. An automatic surveillance system (both for neonates and adults) has a practical medical application. The proposed algorithm is personalized, no fixed reference value being applied, and the algorithm follows the neonate's cardiac rhythm changes. The performance depends on the characteristics of the input ECG. The signal-to-noise ratio of the processed ECG was improved, with a value of up to 10 dB.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8625917PMC
http://dx.doi.org/10.3390/medicina57111199DOI Listing

Publication Analysis

Top Keywords

neonatal intensive
8
medical
5
ecg
5
automated medical
4
medical care
4
care bradycardia
4
bradycardia detection
4
cardiac
4
detection cardiac
4
cardiac monitoring
4

Similar Publications

Hospital to home transition of children with medical complexities in the Netherlands: current practice.

Eur J Pediatr

January 2025

Department of Neonatal & Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus Medical Center - Sophia Children's Hospital, Rotterdam, The Netherlands.

Children with Medical Complexity (CMC) often require 24/7 expert care, which may impede discharge from hospital to home (H2H) resulting in prolonged admission. Limited research exists on pediatric patients with delayed discharges and the underlying reasons for such extended admissions. Therefore, our objectives were to (1) describe the demographics, clinical characteristics, and course of CMC who are in their H2H transition and (2) identify the reasons for postponement of H2H discharge.

View Article and Find Full Text PDF

Arteriovenous malformations (AVMs) are rare congenital vascular malformations with associated morbidities. We describe a neonatal case of upper limb high-flow AVM presenting with upper limb soft tissue mass and postnatal high-output heart failure. Doppler study suggested high-flow AVM, and later magnetic resonance angiography of the right upper limb confirmed the diagnosis.

View Article and Find Full Text PDF

Background: Preclinical studies have documented the role of alpha-adrenergic agonists in myometrial contraction. Phenylephrine is frequently used to prevent and treat post-spinal hypotension during cesarean delivery. We hypothesized phenylephrine would reduce postpartum blood loss due to alpha-1 receptor-mediated uterine and vascular smooth muscle contraction.

View Article and Find Full Text PDF

Early Removal of the Abdominal Patch is Superior to Late Removal in Children With Congenital Diaphragmatic Hernia.

J Pediatr Surg

December 2024

Department of Pediatric Surgery, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, Mannheim 68167, Germany. Electronic address:

Introduction: Open repair of Congenital diaphragmatic hernia (CDH) in neonates often involves reconstruction of the abdominal wall using a patch. Data on predictors for the need of a patch and associated postoperative risks, such as infection or patch detachment, are limited. Specifically, the question regarding the ideal timepoint of patch removal remains unanswered.

View Article and Find Full Text PDF

Introduction: We sought to understand the impact of locum tenens surgeons on pediatric surgical care delivery.

Methods: We conducted a cross-sectional survey of Children's Hospital Association pediatric surgical practices. Anonymous electronic surveys were used to investigate locum tenens utilization, primary reason for use, limitations on clinical activities, and variations in practice standards or quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!