Femoral Head and Liner Exchange in Patients with Atraumatic Dislocation. Results of a Retrospective Study with 6 Years Follow-Up.

Medicina (Kaunas)

Department of Orthopaedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr 200A, 69118 Heidelberg, Germany.

Published: November 2021

: Femoral head and liner exchange is an established treatment for polyethylene wear but has had a more limited role in the treatment of other conditions including dislocation, because of concerns about an increased postoperative dislocation rate. Some authors have considered dislocation associated with polyethylene wear to be a contraindication for this procedure. : Our retrospective review evaluated the outcome of head and liner exchange in a small consecutively operated heterogeneous cohort of 20 patients who presented with dislocation unrelated to trauma, component malposition or component loosening. Of this group, 12 had prior primary total hip arthroplasty, and 8 had prior revision total hip arthroplasty, and included 4 patients with prior revision for dislocation. Mean follow-up was 6 ± 3.5 years (range 1-145 months). : Kaplan-Meier analysis revealed a revision-free implant survival from any cause of 80% (confidence interval 95%:64.3-99.6%) at 5 years after head and liner exchange (index surgery). At final follow-up, 83.3% of patients ( = 10) with prior primary total hip arthroplasty and 62.5% of patients ( = 5) with prior revision total hip arthroplasty, had not required subsequent revision for any cause. None (0%) of the primary total hip arthroplasty group and 3 (38%) of the revision arthroplasty group had required revision for further dislocation. Of the eight revision arthroplasty patients, four had a prior revision for dislocation and three of these four patients required further revision for dislocation after index surgery. The fourth patient had no dislocation after index surgery. One additional patient who had prior revision surgery for femoral component fracture suffered dislocation after index surgery, but was successfully treated with closed reduction. : In our study population, femoral head and liner exchange was an effective treatment option for patients with prior primary total hip arthroplasty and also for a highly select group of revision total arthroplasty patients with no prior history of dislocation. Femoral head and liner exchange does not appear to be a viable treatment option for patients who have had revision total arthroplasty after prior dislocations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617725PMC
http://dx.doi.org/10.3390/medicina57111188DOI Listing

Publication Analysis

Top Keywords

head liner
24
liner exchange
24
total hip
24
hip arthroplasty
24
patients prior
24
prior revision
20
femoral head
16
primary total
16
revision total
16
revision dislocation
16

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!