A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Agreement between Feline Pancreatic Lipase Immunoreactivity and DGGR-Lipase Assay in Cats-Preliminary Results. | LitMetric

The Agreement between Feline Pancreatic Lipase Immunoreactivity and DGGR-Lipase Assay in Cats-Preliminary Results.

Animals (Basel)

Division of Veterinary Epidemiology and Economics, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159c, 02-776 Warsaw, Poland.

Published: November 2021

The colorimetric catalytic assay based on the use of 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) (DGGR) ester as a substrate for pancreatic lipase activity is commonly used for the diagnosis of pancreatitis in dogs and cats. Even though the assay has generally been shown to yield consistent results with feline pancreatic lipase immunoreactivity (fPLI) assay, the agreement may vary between assays of different manufacturers. In this study, the chance-corrected agreement between a DGGR-lipase assay offered by one of the biggest providers of diagnostic solutions in Poland and fPLI assay was investigated. The study was carried out on 50 cats in which DGGR-lipase activity and fPLI were tested in the same blood sample. The chance-corrected agreement was determined using Gwet's AC coefficient separately for the fPLI assay's cut-off values of >3.5 μg/L and >5.3 μg/L. The DGGR-lipase activity significantly positively correlated with fPLI (R = 0.665; CI 95%: 0.451, 0.807, < 0.001). The chance-corrected agreement between the fPLI assay and DGGR-lipase assay differed considerably depending on the cut-off values of the DGGR-lipase assay. When the cut-off value reported in the literature (>26 U/L) was used, it was poor to fair. It was moderate at the cut-off value recommended by the laboratory (>45 U/L), and good at the cut-off value recommended by the assay's manufacturer (>60 U/L). The highest agreement was obtained between the fPLI assay at the cut-off value of 3.5 μg/L and the DGGR-lipase assay at the cut-off value of 55 U/L (AC = 0.725; CI 95%: 0.537, 0.914) and between the fPLI assay at the cut-off value of 5.3 μg/L and the DGGR-lipase assay at the cut-off value of 70 U/L (AC = 0.749; CI 95%: 0.577, 0.921). The study confirms that the chance-corrected agreement between the two assays is good. Prospective studies comparing both assays to a diagnostic gold standard are needed to determine which of them is more accurate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8614432PMC
http://dx.doi.org/10.3390/ani11113172DOI Listing

Publication Analysis

Top Keywords

dggr-lipase assay
24
fpli assay
20
assay cut-off
20
chance-corrected agreement
16
assay
13
pancreatic lipase
12
μg/l dggr-lipase
12
cut-off
9
feline pancreatic
8
lipase immunoreactivity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!