Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
For the first time, we determined the phytochemical profile of alkaloids from using ultraperformance liquid chromatography-quadrupole-time-of-flight-tandem mass spectrometry (UPLC-Q-TOF-MS/MS). A rapid, specific, and sensitive high-performance liquid chromatography-tandem mass spectrometry method was subsequently developed and fully validated for the simultaneous determination of 12 major alkaloid constituents in : pumiloside; naucleoxoside A; naucleoxoside B; nauclefine; angustidine; angustoline; (3,19)-3,14-dihydroangustoline ([]20D: (-)191°); (3,19)-3,14-dihydroangustoline ([]20D: (-)294.7°); strictosamide; angustine; vincosamide; and 3,14-dihydroangustine. The analytes were detected with an electrospray ionization (ESI) source and multiple reaction monitoring (MRM) using positive scanning mode. Three pairs of epimers (naucleoxoside A and naucleoxoside B; (3,19)-3,14-dihydroangustoline ([]20D: (-)191°) and (3,19)-3,14-dihydroangustoline ([]20D: (-)294.7°); and strictosamide and vincosamide) were successfully separated using an ACQUITY UPLC® BEH C column (2.1 mm × 100 mm, 1.7 μm) at 30 °C, with a gradient mobile phase consisting of 0.1% formic acid aqueous solution (A) and acetonitrile (B), a flow rate of 0.2 mL min, and a total run time of 30 min. All calibration curves exhibited excellent linear regression ( > 0.999) within the test range. The precision, repeatability, and stability of the method toward the 12 alkaloid compounds were less than 2.0% in terms of the relative standard deviation (RSD) values. The mean recoveries for all compounds were between 98.7% and 101.1%, with RSD values ranging from 0.55% to 1.7% for samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d1ay01571k | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!