The correlation between graphene characteristic parameters and resonant frequencies by Monte Carlo based stochastic finite element model.

Sci Rep

Département Mécanique, Institut National des Sciences Appliquées de Rouen, 76801, Rouen, France.

Published: November 2021

The uncertainty and fluctuations in graphene characteristic parameters are inevitable issues in both of experimental measurements and numerical investigations. In this paper, the correlations between characteristic parameters (Young's modulus, Poisson's ratio and thickness of graphene) and resonant frequencies are analyzed by the Monte Carlo based stochastic finite element model. Based on the Monte Carlo stochastic sampling procedure, the uncertainty in the characteristic parameters are properly propagated and quantified. The displacements and rotation modes of graphene under the resonant vibration computed by the finite element method are verified. Furthermore, the result robustness of stochastic samples is discussed based on the statistic records and probability density distributions. In addition, both the Pearson and Spearman correlation coefficients of the corresponding characteristic parameters are calculated and compared. The work in this paper provides a feasible and highly efficient method for the characteristic parameter correlation discussion by taking uncertainty into consideration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617261PMC
http://dx.doi.org/10.1038/s41598-021-02429-2DOI Listing

Publication Analysis

Top Keywords

characteristic parameters
20
monte carlo
12
finite element
12
graphene characteristic
8
resonant frequencies
8
carlo based
8
based stochastic
8
stochastic finite
8
element model
8
graphene resonant
8

Similar Publications

Objectives: To compare certain acoustic, aerodynamic, and perceptual parameters before and after an hour-long class to analyze vocal loading characteristics in female Bharatanatyam dance teachers.

Study Design: Prospective study.

Method: The study included 52 female Bharatanatyam dance teachers aged 19 to 40years.

View Article and Find Full Text PDF

The use of active packaging made from biodegradable polymers can contribute to the environment and to the food industry by increasing the shelf life of their products. This study aimed to produce chitosan-based films incorporated with the invertase enzyme (1, 2, 5, 9, and 10 %) as an alternative to avoid sucrose crystallization in the confectionery industry. The optimum activity of the invertase enzyme was observed at 55 °C and pH 5, thus, the films made with the film-forming solution adjusted to pH 5 and dried at 55 °C were compared with those without pH adjustment and dried at room temperature.

View Article and Find Full Text PDF

Nowadays, most of the newly developed active pharmaceutical ingredients (APIs) consist of cohesive particles with a mean particle size of <100μm, a wide particle size distribution (PSD) and a tendency to agglomerate, therefore they are difficult to handle in continuous manufacturing (CM) lines. The current paper focuses on the impact of various glidants on the bulk properties of difficult-to-handle APIs. Three challenging powders were included: two extremely cohesive APIs (acetaminophen micronized (APAPμ) and metoprolol tartrate (MPT)) which previously have shown processing issues during different stages of the continuous direct compression (CDC)-line and a spray dried placebo (SD) powder containing hydroxypropylmethyl cellulose (HPMC), known for its sub-optimal flow with a high specific surface area (SSA) and low density.

View Article and Find Full Text PDF

Preparation and radon exhalation characteristics of fracture granite similar materials in Beishan underground research laboratory.

J Hazard Mater

January 2025

Department of Nuclear Science and Technology, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China.

The mechanism of radon exhalation from surrounding rock fracture has important guiding significance for radon prevention and control in underground research laboratories. The optimal ratio scheme of similar materials in the granite surrounding rock of Beishan underground laboratory was obtained by orthogonal test. The radon exhalation characteristics of fractured rock samples under dry and saturated conditions were obtained by using 10 standard joint roughness coefficient (JRC) curves.

View Article and Find Full Text PDF

Spatially constrained hyperpolarized 13C MRI pharmacokinetic rate constant map estimation using a digital brain phantom and a U-Net.

J Magn Reson

January 2025

UC Berkeley - UCSF Graduate Program in Bioengineering, 1700 4th St, San Francisco, CA 94158, USA; Radiology and Biomedical Imaging, University of California, San Francisco, 1700 4th St, San Francisco, CA 94158, USA.

Fitting rate constants to Hyperpolarized [1-C]Pyruvate (HP C13) MRI data is a promising approach for quantifying metabolism in vivo. Current methods typically fit each voxel of the dataset using a least-squares objective. With these methods, each voxel is considered independently, and the spatial relationships are not considered during fitting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!