Background: Insufficient bone volume around an implant is a common obstacle when dental implant treatment is considered. Limited vertical or horizontal bone dimensions may lead to exposed implant threads following placement or a gap between the bone and implant. This is often addressed by bone augmentation procedures prior to or at the time of implant placement. This study evaluated bone healing when a synthetic TiO block scaffold was placed in circumferential peri-implant defects with buccal fenestrations.

Methods: The mandibular premolars were extracted and the alveolar bone left to heal for 4 weeks prior to implant placement in six minipigs. Two cylindrical defects were created in each hemi-mandible and were subsequent to implant placement allocated to treatment with either TiO scaffold or sham in a split mouth design. After 12 weeks of healing time, the samples were harvested. Microcomputed tomography (MicroCT) was used to investigate defect fill and integrity of the block scaffold. Distances from implant to bone in vertical and horizontal directions, percentage of bone to implant contact and defect fill were analysed by histology.

Results: MicroCT analysis demonstrated no differences between the groups for defect fill. Three of twelve scaffolds were partly fractured. At the buccal sites, histomorphometric analysis demonstrated higher bone fraction, higher percentage bone to implant contact and shorter distance from implant top to bone 0.5 mm lateral to implant surface in sham group as compared to the TiO group.

Conclusions: This study demonstrated less bone formation with the use of TiO scaffold block in combination with implant placement in cylindrical defects with buccal bone fenestrations, as compared to sham sites.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8620131PMC
http://dx.doi.org/10.1186/s40824-021-00245-3DOI Listing

Publication Analysis

Top Keywords

implant placement
16
implant
14
bone
14
bone implant
12
defect fill
12
vertical horizontal
8
block scaffold
8
defects buccal
8
cylindrical defects
8
tio scaffold
8

Similar Publications

Deproteinized Bovine Bone Mineral With Collagen for Anterior Maxillary Ridge Augmentation: A Retrospective Cohort Study.

Clin Implant Dent Relat Res

February 2025

Department of Implantology, The Affiliated Hospital of Stomatology, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, China.

Objectives: This study aimed to assess the effects of deproteinized bovine bone mineral with collagen (DBBMC) combined with deproteinized bovine bone mineral (DBBM) on facial alveolar bone augmentation in the anterior maxillary region.

Materials And Methods: Patients receiving dental implant placement with simultaneous lateral bone augmentation using DBBM (control group) or DBBMC combined with DBBM (test group) were included in the study. The radiographic assessment of facial alveolar bone, such as facial horizontal bone thickness (FHBT), facial vertical bone level (FVBL), and square of facial bone (SFB), was taken by cone beam computed tomography (CBCT).

View Article and Find Full Text PDF

Statement Of Problem: The impact of free gingival graft (FGG) dimensions on the postsurgical shrinkage of keratinized tissue width (KTW) and surface area in posterior implant sites is unclear. Standardized assessments of how graft dimensions influence KTW and surface area shrinkage rates over a 6-month period after FGG are lacking.

Purpose: The purpose of this prospective parallel cohort study was to examine the impact of the graft dimensions on the postsurgical shrinkage of KTW and surface area over a 6-month follow-up period after FGG in the posterior regions.

View Article and Find Full Text PDF

Statement Of Problem: Digital surgical guides improve precision by detailing the direction, position, and angle of implants, which reduces surgery time and complications. A bibliometric analysis of guided surgery in implant dentistry is lacking.

Purpose: The aim of this metrics-based analysis was to analyze the trends and key characteristics of articles related to guided surgery in implant dentistry.

View Article and Find Full Text PDF

A prediction method and evaluation for assessing guide-supported dental implant accuracy.

Comput Methods Biomech Biomed Engin

February 2025

Zhejiang Weilian Technology Co., Ltd, Jiaxing, China.

Functional and esthetic results require accurate implant placement. We aimed to develop a predictive method for assessing dental implant accuracy, and to evaluate the cumulative system influence of surgical guides. A mathematical model was constructed to determine the influence of surface changes on a specific point, using Jacobian matrix expressions.

View Article and Find Full Text PDF

Background: The placement of breast implants in a prepectoral plane has become increasingly popular in breast reconstruction, although data on how this affects radiation delivery in women with breast cancer are limited. This study aimed to assess the dosimetric differences in radiation plans for immediate breast reconstruction between prepectoral and subpectoral implants.

Methods: In this study, a retrospective review and dosimetric analysis of patients with breast cancer who underwent immediate implant-based reconstruction and postmastectomy radiation therapy (PMRT) were performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!