In this chapter, we discuss the issue of balance between spatial resolution and computational efficiency in the context of the R-SWMS model. Based on the equations governing the water fluxes within the model, we propose here an objective and quantitative criterion which can help fix root segment size to both minimize computational load and achieve simulation according to a given accuracy degree.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-0716-1816-5_14DOI Listing

Publication Analysis

Top Keywords

spatial resolution
8
define appropriate
4
appropriate spatial
4
resolution root
4
root segments
4
segments solving
4
solving water
4
water flow
4
flow root
4
root system
4

Similar Publications

A superresolution (SR) method for the reconstruction of Navier-Stokes (NS) flows from noisy observations is presented. In the SR method, first the observation data are averaged over a coarse grid to reduce the noise at the expense of losing resolution and, then, a dynamic observer is employed to reconstruct the flow field by reversing back the lost information. We provide a theoretical analysis, which indicates a chaos synchronization of the SR observer with the reference NS flow.

View Article and Find Full Text PDF

Cooling of Semiconductor Devices via Quantum Tunneling.

Phys Rev Lett

December 2024

Massachusetts Institute of Technology, Research Laboratory of Electronics, Cambridge, Massachusetts 02139, USA.

Classical transport of electrons and holes in nanoscale devices leads to heating that severely limits performance, reliability, and efficiency. In contrast, recent theory suggests that interband quantum tunneling and subsequent thermalization of carriers with the lattice results in local cooling of devices. However, internal cooling in nanoscale devices is largely unexplored.

View Article and Find Full Text PDF

Purpose: Trophoblast cell-surface antigen 2 (Trop2) is overexpressed in various solid tumors and contributes to tumor progression, while its expression remains low in normal tissues. Trop2-targeting antibody-drug conjugate (ADC), sacituzumab govitecan-hziy (Trodelvy), has shown efficacy in targeting this antigen. Leveraging the enhanced specificity of ADCs, we conducted the first immunoPET imaging study of Trop2 expression in gastric cancer (GC) and triple-negative breast cancer (TNBC) models using Zr-labeled Trodelvy ([Zr]Zr-DFO-Trodelvy).

View Article and Find Full Text PDF

Coronary artery disease (CAD) remains a leading cause of morbidity and mortality worldwide, necessitating advancements in diagnostic techniques. Coronary CT angiography (CCTA) has emerged as a pivotal non-invasive tool for evaluating coronary artery anatomy and detecting atherosclerotic plaque burden with high spatial resolution. This review explores the evolution of CCTA, highlighting its technological advancements, clinical applications, and challenges.

View Article and Find Full Text PDF

Understanding and modeling of gas puff injection for diagnostic purposes.

Rev Sci Instrum

January 2025

Max-Planck-Institut für Plasmaphysik, Garching 85748, Germany.

This article presents an experimental setup capable of providing high spatial and temporal resolution measurements of neutral gas puff injection using a glow discharge to excite the neutral gas and an ultra-high-speed camera to record the emitted light. Using the proposed setup, the shape and propagation velocity of a thermal deuterium gas puff at 1 bar have been measured. The cloud has a conical shape and a propagation velocity of vprop = 1870 ± 270 m/s.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!