Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hawthorn (.) has been used for the treatment of several heart diseases and hypertension. The studies carried out on several hawthorn species have led to the development of standardized extracts useful in the cure of mild chronic cardiac diseases. In Mexico, the most common species are and . Decoctions prepared from the fruits and leaves of these species have been employed to the treat respiratory diseases, tachycardia and to improve coronary blood flow. Considering that to date there are no reports of the use of Mexican species to treat cardiovascular diseases, we propose an analytical method to obtain a quantified extract of leaves for the development of a standardized extract with therapeutic value in cardiovascular diseases as an alternative source to the extracts obtained from species of European and Asian origin. Therefore, the aim of this study was to obtain an extract prepared from C. mexicana leaves with the highest vasodilator activity to select the optimal chemical marker to stablish and validate a reversed-phase high-performance liquid chromatography (RPHPLC-DAD) analytical method for obtaining a quantified extract with vasodilator effect. The results obtained from the analytical method validation, which was carried out according to the guidelines stablished in the Eurachem Guide and the ICH guidelines proved that the RPHPLC-DAD method we developed was specific, precise, accurate, and showed good linearity over the concentration range of 3 - 21 µg/ml for (-)-epicatechin and rutin, which were selected as chemical markers.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596289 | PMC |
http://dx.doi.org/10.1016/j.jsps.2021.10.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!