Contrast-enhanced digital mammography (CEDM) has been shown to outperform standard mammography while performing comparably to contrast-enhanced MRI. The purpose of our study was to compare imaging characteristics of false-positive and true-positive findings on CEDM. This retrospective study included women who underwent baseline screening CEDM between January 2013 and December 2018 assessed as BI-RADS category 0, 3, 4, or 5 and who underwent biopsy with histopathologic diagnosis or had a 2-year imaging follow-up. Lesion characteristics were extracted from CEDM reports. A true-positive finding was defined as a lesion in which biopsy yielded malignancy. A false-positive finding was defined as a lesion in which biopsy yielded benign or benign high-risk pathology or in which 2-year imaging follow-up was negative. Of 157 patients (median age, 52 years), 24 had a total of 26 true-positive lesions, and 133 had a total of 147 false-positive lesions. Of the 26 true-positive lesions, one (4%) exhibited only a mammographic finding on low-iodine images, 13 (50%) exhibited only a contrast finding on iodine images, and 12 (46%) exhibited both a mammographic finding on low-energy images and a contrast finding on iodine images. A true-positive result was more likely ( = .02) for lesions present on both low-energy images and iodine images (31%) than on low-energy images only (4%) or iodine images only (12%). Among lesions present on both low-energy and iodine images, a true-positive result was more likely ( < .001) when the type of mammographic finding was an asymmetry (46%) or calcification (80%) than a mass (11%) or distortion (0%). A true-positive result was more likely ( = .01) among those with, versus those without, an ultrasound correlate (36% vs 9%) and also was more likely ( = .02) among those with, versus those without, an MRI correlate (18% vs 2%). Of 25 false-positive calcifications, 24 had no associated mammographic enhancement; of five true-positive calcifications, four had mammographic enhancement. A low-energy mammographic finding with associated enhancement or a finding with a sonographic or MRI correlate predicts a true-positive result. Calcifications with associated enhancement had a high malignancy rate. Nonetheless, half of true-positive lesions enhanced on iodine images without a mammographic finding on low-energy images. These observations inform radiologists' management of abnormalities detected on screening CEDM.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9110098 | PMC |
http://dx.doi.org/10.2214/AJR.21.26847 | DOI Listing |
Abdom Radiol (NY)
January 2025
Department of Radiology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute,. Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610000, Chengdu, China.
Objective: This study evaluates the potential of dual-energy CT (DECT) for preoperative prediction of tumor budding (TB) and lymphovascular invasion (LVI) in colon cancer.
Methods: This prospective study enrolled 153 patients (mean age 61.33 years ± 0.
Eur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Sci Rep
January 2025
Department of Botany, Guru Ghasidas Vishwavidyalaya, (A Central University) Koni, Bilaspur, C.G, 495009, India.
This study addresses the pervasive issue of particulate matter (PM) emission in urban areas, proposing a better approach using scanning electron microscope (SEM) techniques to identify plant species effective in airborne PM removal. Conducted in Bilaspur city, the research strategically selected six plant species across four distinct sites and applied the SEM-Image J method for analysis, yielding significant insights, especially in the respirable PM range. Among the tested plant species, Senna Siamea and Dalbergia Sissoo emerged as consistent and standout performers, displaying the highest PM removal efficiency across all sites.
View Article and Find Full Text PDFRev Med Liege
January 2025
Service de Radiodiagnostic, CHU Liège, Belgique.
In the event of a prevascular mediastinal mass, knowledge of the anatomy and content of the mediastinum is an essential prerequisite to establish a differential diagnosis. The «4T» rule is applicable because it is a simple and effective mnemonic. It groups together; thyroid goiter, terrible lymphoma, teratoma and thymoma.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Department of Medical Physics, Jeroen Bosch Ziekenhuis, Henri Dunantstraat 1, 's-Hertogenbosch, 5223GZ, NETHERLANDS.
The treatment of breast cancer during pregnancy requires careful consideration of consequences for both maternal and fetal health. In non-pregnant patients, the use of radioactive iodine-125 (125I)-seeds is standard practice for localising non-palpable breast tumors before breast-conserving surgery. However, the use of 125I-seeds in pregnant patients has been avoided due to concerns about fetal radiation exposure.