A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usefulness of Multisite Ventricular Pacing in Nonresponders to Cardiac Resynchronization Therapy. | LitMetric

Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients with myocardial dysfunction and delayed ventricular activation, but approximately 25% to 40% of patients do not respond to CRT. Left ventricular (LV) multisite pacing (MSP) has been proposed as a tool to improve CRT response. The goal of this study is to examine the safety and efficacy of LV MSP in CRT nonresponders. Between January 2018, and September 2019, the Strategic Management to Improve CRT Using Multi-Site Pacing trial prospectively enrolled 584 CRT-defibrillator recipients for established indications at 52 sites across the United States and evaluated their response at 6 months using the clinical composite score (CCS). Of the nonresponders, 102 patients had the LV MSP feature turned on and 78 patients completed the 12-month CCS evaluation. The LV MSP feature-related complication-free rate was 99.0% with a lower 95% confidence interval limit of 94.9%, which was higher than the performance goal of 90%. The proportion of nonresponders with an improved CCS from 6 to 12 months was 51.3% with a lower 95% confidence interval limit of 41.4%, which was higher than the performance goal of 5%. The estimated mean reduction in battery longevity with the LV MSP feature was about 3.6 months (estimated battery longevity of 8.87 ± 2.08 years at 6 months and 8.07 ± 2.23 years at 12 months). In conclusion, in CRT nonresponders, the use of the LV MSP feature is safe and associated with a ∼50% conversion rate with a small projected reduction in CRT-defibrillator battery longevity. LV MSP should be considered in the management of CRT nonresponders.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2021.10.027DOI Listing

Publication Analysis

Top Keywords

crt nonresponders
12
msp feature
12
battery longevity
12
cardiac resynchronization
8
resynchronization therapy
8
improve crt
8
lower 95%
8
95% confidence
8
confidence interval
8
interval limit
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!