Background: Smaller randomized studies have reported conflicting results regarding the optimal electrode position for cardioverting atrial fibrillation. However, anterior-posterior electrode positioning is widely used as a standard and believed to be superior to anterior-lateral electrode positioning. Therefore, we aimed to compare anterior-lateral and anterior-posterior electrode positioning for cardioverting atrial fibrillation in a multicenter randomized trial.
Methods: In this multicenter, investigator-initiated, open-label trial, we randomly assigned patients with atrial fibrillation scheduled for elective cardioversion to either anterior-lateral or anterior-posterior electrode positioning. The primary outcome was the proportion of patients in sinus rhythm after the first shock. The secondary outcome was the proportion of patients in sinus rhythm after up to 4 shocks escalating to maximum energy. Safety outcomes were any cases of arrhythmia during or after cardioversion, skin redness, and patient-reported periprocedural pain.
Results: We randomized 468 patients. The primary outcome occurred in 126 patients (54%) assigned to the anterior-lateral electrode position and in 77 patients (33%) assigned to the anterior-posterior electrode position (risk difference, 22 percentage points [95% CI, 13-30]; <0.001). The number of patients in sinus rhythm after the final cardioversion shock was 216 (93%) assigned to anterior-lateral electrode positioning and 200 (85%) assigned to anterior-posterior electrode positioning (risk difference, 7 percentage points [95% CI, 2-12]). There were no significant differences between groups in any safety outcomes.
Conclusions: Anterior-lateral electrode positioning was more effective than anterior-posterior electrode positioning for biphasic cardioversion of atrial fibrillation. There were no significant differences in any safety outcome. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03817372.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.121.056301 | DOI Listing |
Laryngoscope
December 2024
Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, U.S.A.
Objectives: Cochlear implant array malpositioning is associated with impaired speech perception, vertigo, and facial nerve stimulation. Tip fold-over is a subset of malpositioning that occurs more often with perimodiolar electrodes, but historically it has not been characterized due to lack of knowledge regarding electrode movements of the electrode within the cochlea. The aim of this study was to characterize the mechanics of tip fold-over events and their associated insertion pressure profiles.
View Article and Find Full Text PDFSoc Neurosci
December 2024
Cosmic Lab, Department of Philosophy, Communication and Performing Arts, "Roma Tre" University, Rome, Italy.
Several studies showed a positive effect of stories on Theory of Mind (ToM) performance. The aim of the present exploratory study was to investigate whether and how a specific aspect of narrative, i.e.
View Article and Find Full Text PDFEpilepsia
December 2024
Department of Clinical Neurophysiology, Danish Epilepsy Centre Filadelfia, Dianalund, Denmark.
Objective: EEG patterns and quantitative EEG (qEEG) features have been poorly explored in monogenic epilepsies. Herein, we investigate regional differences in EEG frequency composition in patients with STXBP1 developmental and epileptic encephalopathy (STXBP1-DEE).
Methods: We conducted a retrospective study collecting electroclinical data of patients with STXBP1-DEE and two control groups of patients with DEEs of different etiologies and typically developing individuals matched for age and sex.
JAMA Netw Open
September 2024
Department of Emergency Medicine, Oregon Health and Science University, Portland.
Importance: Ventricular fibrillation (VF) or pulseless ventricular tachycardia (pVT) are the most treatable causes of out-of-hospital cardiac arrest (OHCA). Yet, it remains unknown if defibrillator pad position, placement in the anterior-posterior (AP) or anterior-lateral (AL) locations, impacts patient outcomes in VF or pVT OHCA.
Objective: To determine the association between initial defibrillator pad placement position and OHCA outcomes for patients presenting with VF or pVT.
J Am Heart Assoc
July 2024
Department of Cardiovascular Medicine, William Beaumont University Hospital Corewell Health East Royal Oak MI USA.
Background: Anterior-posterior electrode placement is preferred in electrical cardioversion of atrial fibrillation. However, the optimal anterior-posterior electrode position in relation to the heart is not studied.
Methods And Results: We performed a prospective observational study on patients presenting for cardioversion of atrial fibrillation.