The real-time multi-emitter localization method is essential for advancing high-throughput super-resolution localization microscopy (HT-SRLM). In the past decade, the graphics processing unit (GPU) computation has been dominantly used to accelerate the execution speed of the multi-emitter localization method. However, if HT-SRLM is combined with a scientific complementary metal-oxide-semiconductor (sCMOS) camera working at full frame rate, real-time image processing is still difficult to achieve using this acceleration approach, thus resulting in a massive data storage challenge and even system crash. Here we take advantage of the cooperative acceleration power of field programming gate array (FPGA) computation and GPU computation, and propose a method called HCP-STORM to enable real-time multi-emitter localization. Using simulated images, we verified that HCP-STORM is capable of providing real-time image processing for raw images from a representative Hamamatsu Flash 4 V3 sCMOS camera working at full frame rate (that is, 2048×2048 pixels @ 10 ms exposure time). Using experimental images, we prove that HCP-STORM is 25 times faster than QC-STORM and 295 times faster than ThunderSTORM, with a small but acceptable degradation in image quality. This study shows the potential of FPGA-GPU cooperative computation in accelerating multi-emitter localization, and pushes a significant step toward the maturity of HT-SRLM technology.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.439976DOI Listing

Publication Analysis

Top Keywords

multi-emitter localization
20
accelerating multi-emitter
8
super-resolution localization
8
localization microscopy
8
fpga-gpu cooperative
8
cooperative computation
8
real-time multi-emitter
8
localization method
8
gpu computation
8
scmos camera
8

Similar Publications

Single molecule localization (SML) and tracking (SPT) techniques, such as (spt)PALM, (u/DNA)PAINT and quantum dot tracking, have given unprecedented insight into the nanoscale molecular organization and dynamics in living cells. They allow monitoring individual proteins with millisecond temporal resolution and high spatial resolution (<30 nm) by precisely localizing the point spread function (PSF) of individual emitters and tracking their position over time. While SPT methods have been extended to study the temporal dynamics and co-organization of multiple proteins, conventional experimental setups are restricted in the number of proteins they can probe simultaneously and usually have to tradeoff between the number of colors, the spatio-temporal resolution, and the field of view.

View Article and Find Full Text PDF

PCIe-based FPGA-GPU heterogeneous computation for real-time multi-emitter fitting in super-resolution localization microscopy.

Biomed Opt Express

June 2022

Key Laboratory of Biomedical Engineering of Hainan Province, School of Biomedical Engineering, Hainan University, Haikou 570228, China.

Real-time multi-emitter fitting is a key technology for advancing super-resolution localization microscopy (SRLM), especially when it is necessary to achieve dynamic imaging quality control and/or optimization of experimental conditions. However, with the increase of activation densities, the requirements in the computing resources would increase rapidly due to the complexity of the fitting algorithms, making it difficult to realize real-time multi-emitter fitting for emitter density more than 0.6 mol/µm in large field of view (FOV), even after acceleration with the popular Graphics Processing Unit (GPU) computation.

View Article and Find Full Text PDF

The real-time multi-emitter localization method is essential for advancing high-throughput super-resolution localization microscopy (HT-SRLM). In the past decade, the graphics processing unit (GPU) computation has been dominantly used to accelerate the execution speed of the multi-emitter localization method. However, if HT-SRLM is combined with a scientific complementary metal-oxide-semiconductor (sCMOS) camera working at full frame rate, real-time image processing is still difficult to achieve using this acceleration approach, thus resulting in a massive data storage challenge and even system crash.

View Article and Find Full Text PDF

An outstanding challenge in single-molecule localization microscopy is the accurate and precise localization of individual point emitters in three dimensions in densely labeled samples. One established approach for three-dimensional single-molecule localization is point-spread-function (PSF) engineering, in which the PSF is engineered to vary distinctively with emitter depth using additional optical elements. However, images of dense emitters, which are desirable for improving temporal resolution, pose a challenge for algorithmic localization of engineered PSFs, due to lateral overlap of the emitter PSFs.

View Article and Find Full Text PDF

Multi-emitter localization has great potential for maximizing the imaging speed of super-resolution localization microscopy. However, the slow image analysis speed of reported multi-emitter localization algorithms limits their usage in mostly off-line image processing with small image size. Here we adopt the well-known divide and conquer strategy in computer science and present a fitting-based method called QC-STORM for fast multi-emitter localization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!