A new timing detection method based on acousto-optic modulation is demonstrated. The timing detector is immune to dispersion effects and the environmental and laser amplitude noise can be well suppressed by a balanced configuration. With 1 mW power per pulse train, the measured timing noise floor is about 1×10 fs/Hz, which is close to the shot noise limit. The integrated timing jitter is 26 as at [1 Hz, 1 MHz]. With 170 fs pulse width and typical detector parameters, the calculated detector's timing noise floor is more than 5 and 12 orders of magnitude lower than that of a BOC, at 1 mW and 1 µW input power, respectively. This timing detector has a variety of potential applications in ultra-long fiber link stabilization, quantum metrology, weak signal timing control, etc.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.442459DOI Listing

Publication Analysis

Top Keywords

timing detector
12
timing
8
timing noise
8
noise floor
8
attosecond-precision balanced
4
balanced linear-optics
4
linear-optics timing
4
detector
4
detector timing
4
timing detection
4

Similar Publications

Background: Atrial fibrillation (AF) has a significant impact on health and quality of life. The relationship of AF burden and temporal patterns of AF on patient symptoms, outcomes, and healthcare utilization is unknown. Insertable cardiac monitors (ICMs) are a strategic and as yet untapped, tool to investigate these relationships.

View Article and Find Full Text PDF

This article reports a 110.2 MHz ultra-low-power phase-locked loop (PLL) for MEMS timing/frequency reference oscillator applications. It utilizes a 6.

View Article and Find Full Text PDF

Time resolution is crucial in positron emission tomography (PET) to enhance the signal-to-noise ratio and image quality. Moreover, high sensitivity requires long scintillators, which can cause distortions in the reconstructed images due to parallax effects. This study evaluates the performance of a time-of-flight (TOF)-PET module that makes use of a single-side readout of a 4x4 3.

View Article and Find Full Text PDF

High spatial resolution PET detectors based on 10 mm × 10 mm linearly-graded SiPMs and 0.5 mm pitch LYSO arrays.

Phys Med Biol

December 2024

Department of Biomedical Engineering, University of California Davis, 451 East Health Science Drive, Davis, California, 95616, UNITED STATES.

Position-sensitive silicon photomultipliers (PS-SiPMs) are promising photodetectors for ultra-high spatial resolution small-animal positron emission tomography (PET) scanners. This paper evaluated the performance of the latest generation of linearly-graded SiPMs (LG-SiPMs), a type of PS-SiPM, for ultra-high spatial resolution PET applications using LYSO arrays from two vendors. Approach: Two dual-ended readout detectors were developed by coupling LG-SiPMs to both ends of the two LYSO arrays.

View Article and Find Full Text PDF

Novel high-stopping power scintillators for medical applications.

Proc SPIE Int Soc Opt Eng

February 2024

Radiation Monitoring Devices, Inc., 44 Hunt St., Watertown, MA, USA 02472- 4624.

Development of new scintillator materials is a continuous effort, which recently has been focused on materials with higher stopping power. Higher stopping power can be achieved if the compositions include elements such as Tl (Z=81) or Lu (Z=71), as the compounds gain higher densities and effective atomic numbers. In context of medical imaging this translates into high detection efficiency (count rates), therefore, better image quality (statistics, thinner films) or lower irradiation doses to patients in addition to lowering of cost.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!