A new flat detector and pulsed fluoroscopy technology is available to further reduce radiation exposure in radiological monitoring during scoliosis treatment in children and adolescents. The aim of this study is to compare different settings of the system (opening area(OA) and image quality settings (IQS)) in order to find the optimal parameters with high image quality and the lowest possible radiation exposure. Therefore, we examined four cadaver spines (T1 to sacrum) with the flat detector technique using digital pulsed fluoroscopy and simulated the abdominal soft tissues. The images were merged and evaluated by three different investigators using an established scoring system. For comparison, we used digital radiography images of the cadaver spines. The values for the DAP increased from the small OA (33% ; 0.56 µGy·m²) to the maximum OA (100% ; 0.82 µGy·m²) by 45% (p = .003) and from the low image quality setting (0.57 µGy·m²) to the high setting (0.84 µGy·m²) by 48% (p = .028). Despite the low DAP, the setting 33% OA achieved the best point values for image quality, therefore this setting is clearly preferred. Using a digital fluoroscopy system allows a significant reduction of radiation exposure by a factor of 7.5 (3.88µGy·m² to 0.5µGy·m²) compared to slot- scanning x-ray (EOS). Due to this success, the flat detector and pulsed fluoroscopy technology can be an alternative to established methods such as X-ray and EOS in clinical use.

Download full-text PDF

Source

Publication Analysis

Top Keywords

radiation exposure
16
flat detector
16
pulsed fluoroscopy
16
image quality
16
detector pulsed
12
fluoroscopy technology
12
reduction radiation
8
cadaver spines
8
quality setting
8
x-ray eos
8

Similar Publications

Chest imaging in children presents unique challenges due to varying requirements across age groups. For chest radiographs, achieving optimal images often involves careful positioning and immobilisation techniques. Antero-posterior projections are easier to obtain in younger children, while lateral decubitus radiographs are sometimes used when expiratory images are difficult to obtain and for free air exclusion.

View Article and Find Full Text PDF

Variable stressor exposure shapes fitness within and across generations.

Sci Rep

January 2025

Aquatic Ecology, Department of Biology, Lund University, Lund, Sweden.

Environmental variation has long been considered a key driver of evolutionary change, predicted to shape different strategies, such as genetic specialization, plasticity, or bet-hedging to maintain fitness. However, little evidence is available with regards to how the periodicity of stressors may impact fitness across generations. To address this gap, I conducted a reciprocal split-brood experiment using the freshwater crustacean, Daphnia magna, and an ecologically relevant environmental stressor, ultraviolet radiation (UVR).

View Article and Find Full Text PDF

Three-dimensional diffractive acoustic tomography.

Nat Commun

January 2025

Department of Biomedical Engineering, Duke University, Durham, NC, USA.

Acoustically probing biological tissues with light or sound, photoacoustic and ultrasound imaging can provide anatomical, functional, and/or molecular information at depths far beyond the optical diffusion limit. However, most photoacoustic and ultrasound imaging systems rely on linear-array transducers with elevational focusing and are limited to two-dimensional imaging with anisotropic resolutions. Here, we present three-dimensional diffractive acoustic tomography (3D-DAT), which uses an off-the-shelf linear-array transducer with single-slit acoustic diffraction.

View Article and Find Full Text PDF

Assessment of Hsp90β-selective inhibitor safety and on-target effects.

Sci Rep

January 2025

Department of Chemistry and Biochemistry, The University of Notre Dame, 305 McCourtney Hall, Notre Dame, IN, 46556, USA.

The heat shock protein 90 (Hsp90) family of molecular chaperones mediates the folding and activation of ~ 400 client proteins, many of which contribute to oncogenesis. As a result, Hsp90 pan-inhibitors, which inhibit all four Hsp90 isoforms, have been investigated in the clinic for the treatment of cancer. Unfortunately, detrimental side effects were observed and hindered the clinical development of pan-Hsp90 inhibitors.

View Article and Find Full Text PDF

Effect of UV exposure on DNA deposited on drug capsules.

Forensic Sci Int

January 2025

College of Science and Engineering, Flinders University, Bedford Park, South Australia 5042, Australia.

Illicit drugs are often made in less-than-sterile environments and can be stored in ways which can be detrimental to any DNA present, such as whether they are exposed to UV radiation. Previously, analysis of how exposure to UV impacted DNA for forensic applications has been in controlled laboratory conditions isolating a single component of UV radiation and often on DNA-rich samples such as bloodstains or saliva. To evaluate DNA persistence in more realistic conditions, capsules, such as those used to distribute controlled substances, were manually made and then packed into ziplock bags.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!