A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry. | LitMetric

Purpose: To analyze the agreement of the predicted intraocular lens (IOL) power obtained with ANTERION, IOLMaster 700 and Pentacam AXL biometers.

Methods: We calculated the monofocal and trifocal IOL power using the SRK/T, Haigis, Barrett Universal II and Hoffer Q formulas for 106 eyes. IOL power agreement between devices was evaluated using the Bland-Altman method.

Results: We found significant differences between biometers comparisons ( < 0.001). ANTERION and IOLMaster 700 did not produce significant IOL power differences ( > 0.05), with the same outcomes for medium- and long-eyes. No significant differences were found using the SRK/T, Haigis, or Hoffer Q formulas for short-eyes ( > 0.1). However, Barrett Universal II formula produced significant differences ( < 0.05) and these differences lay between the ANTERION and Pentacam AXL. ANTERION versus IOLMaster 700 comparison showed limits of agreement (LoA) varying from 1.1071D in SRK/T monofocal medium-eyes to 1.6828D in Hoffer Q trifocal all-eyes. The largest LoA (about 3.0D) was found for short-eyes when comparing the Pentacam AXL with the other two devices.

Conclusions: These devices provided statistically significant but clinically insignificant mean differences in predicted IOL power. However, wide LoA values suggest that for specific eyes these outcomes could be clinically significant.

Download full-text PDF

Source
http://dx.doi.org/10.1080/17434440.2021.2008908DOI Listing

Publication Analysis

Top Keywords

iol power
12
agreement predicted
8
predicted intraocular
8
intraocular lens
8
srk/t haigis
8
barrett universal
8
hoffer formulas
8
power
4
lens power
4
power swept-source
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!