A simplified CT-volumetry method for the canine liver.

Vet Radiol Ultrasound

Royal (Dick) School of Veterinary Studies and Roslin Institute, The University of Edinburgh, Roslin, UK.

Published: January 2022

Computed tomographic (CT) liver volumetry using the slice addition technique is an accurate, but a time-consuming method. Commonly used DICOM-viewing software only allows contouring of one area per image, which can be troublesome in the transverse plane as different lobes are separated. In this prospective, experimental, methods comparison study, we aimed to determine if hepatic contouring using sagittal reformatting and a reduced number of images would yield accurate results. Computed tomographic studies were performed in five canine cadavers and reviewed using sagittal reformatting. For each dog, the number of images that included the liver was used to create four stacks with progressively fewer images in which the liver would be contoured, each with the following median number of images: A: 60, B: 31, C: 16, and D: 9. Liver volume was calculated by three observers using the different stacks of images. After CT examination, the cadavers were dissected, the liver was removed, and its volume was determined by water displacement. Single score intraclass correlation coefficient was calculated to assess interobserver agreement. Kruskal-Wallis test was used to compare water displacement and CT-based volumes. There was excellent agreement between observers (intraclass correlation coefficient = 0.957; 95% confidence interval, 0.908-0.982, P < 0.0001). No significant difference was found between the volumes obtained by CT-volumetry using each of the stacks and the volumes obtained by water displacement. Using sagittally reformatted images and hepatic contouring in as few as nine images can be an accurate and simple method for CT-volumetry of the canine liver.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vru.13018DOI Listing

Publication Analysis

Top Keywords

number images
12
computed tomographic
8
sagittal reformatting
8
images liver
8
water displacement
8
intraclass correlation
8
liver
6
images
5
simplified ct-volumetry
4
ct-volumetry method
4

Similar Publications

Giant encephalocele in newborns: prenatal diagnosis, management and outcome.

Childs Nerv Syst

January 2025

Department of Global Health, Faculty of Health Sciences, McMaster University, 1280 Main St W, Hamilton, ON, L8S 4L8, Canada.

Background: A giant encephalocele associated with Chiari malformation is a rare congenital anomaly from a cephalad neural tube defect. Early prenatal diagnosis and parental counseling are essential; as early surgical intervention can improve outcomes.

Methods: Between 2010 and 2023, twenty-seven newborns out of 43,815 delivered at our institution were diagnosed with encephaloceles, including seven cases of giant encephalocele associated with Chiari malformation type III.

View Article and Find Full Text PDF

A 36-year-old woman diagnosed with complicated cholecystolithiasis underwent elective laparoscopic cholecystectomy (LC), then converted to open cholecystectomy because of a massive intraoperative bleeding. Hemostasis was performed with clipping and suturing the source of bleeding. In post-operative period, the patient suffered from persistent anemia associated with hemoperitoneum diagnosed through abdominal CT scanning, in absence of any sign of active bleeding.

View Article and Find Full Text PDF

Development of an image quality evaluation system for bedside chest X-ray images using scatter correction processing.

Radiol Phys Technol

January 2025

Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-ogu, Arakawa, Tokyo, 116-8551, Japan.

In plain radiography, scattered X-ray correction processing (Virtual Grid: VG) is used to estimate and correct scattered rays in images. We developed an objective evaluation system for bedside chest X-ray images using VG and investigated its usefulness. First, we trained the blind/referenceless image spatial quality evaluator (BRISQUE) on 200 images obtained by portable chest radiography.

View Article and Find Full Text PDF

Detecting Hemorrhagic Myocardial Infarction With 3.0-T CMR: Insights Into Spatial Manifestation, Time-Dependence, and Optimal Acquisitions.

JACC Cardiovasc Imaging

January 2025

Department of Radiology and Imaging Sciences and Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA. Electronic address:

Background: Hemorrhagic myocardial infarction (hMI) can rapidly diminish the benefits of reperfusion therapy and direct the heart toward chronic heart failure. T2∗ cardiac magnetic resonance (CMR) is the reference standard for detecting hMI. However, the lack of clarity around the earliest time point for detection, time-dependent changes in hemorrhage volume, and the optimal methods for detection can limit the development of strategies to manage hMI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!