A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dosimetric Uncertainties in Dominant Intraprostatic Lesion Simultaneous Boost Using Intensity Modulated Proton Therapy. | LitMetric

Purpose: While intensity modulated proton therapy can deliver simultaneous integrated boost (SIB) to the dominant intraprostatic lesion (DIL) with high precision, it is sensitive to anatomic changes. We investigated the dosimetric effects from these changes based on pretreatment cone-beam computed tomographic (CBCT) images and identified the most important factors using a multilayer perceptron neural network (MLPNN).

Methods And Materials: DILs were contoured based on coregistered multiparametric magnetic resonance images for 25 previously treated prostate cancer patients. SIB plans were created with (1) prostate clinical target volume - V70 Gy = 98%; (2) DIL - V98 Gy > 95%; and (3) all organs at risk (OARs)"?> within clinical constraints. SIB plans were applied to daily CBCT-based deformed planning computed tomography (CT)"?>. DIL - V98 Gy, bladder/rectum maximum dose (Dmax) and volume changes, femur shifts, and the distance from DIL to organs at riskOARs"?> in both planning computed tomogramsCT"?> and CBCT were calculated. Wilcoxon signed-ranks tests were used to compare the changes. MLPNNs were used to model the change in ΔDIL - V98 Gy > 10% and bladder/rectum Dmax > 80 Gy, and the relative importance factors for the model were provided. The performances of the models were evaluated with receiver operating characteristic curves.

Results: Comparing initial plan to the average from evaluation plans, respectively, DIL - V98 Gy was 89.3% ± 19.9% versus 86.2% ± 21.3% ( = .151); bladder Dmax 71.9 ± 0.6 Gy versus 74.5 ± 2.9 Gy ( < .001); and rectum Dmax 70.1 ± 2.4 Gy versus 74.9 ± 9.1Gy ( = .007). Bladder and rectal volumes were 99.6% ± 39.5% and 112.8% ± 27.2%, respectively, of their initial volume. The femur shift was 3.16 ± 2.52 mm. In the modeling of ΔDIL V98 Gy > 10%, DIL to rectum distance changes, DIL to bladder distance changes, and rectum volume changes ratio are the 3 most important factors. The areas under the receiver operating characteristic curves were 0.89, 1.00, and 0.99 for the modeling of ΔDIL - V98 Gy > 10%, and bladder and rectum Dmax > 80 Gy, respectively.

Conclusions: Dosimetric changes in DIL SIB with intensity modulated proton therapy can be modeled and classified based on anatomic changes on pretreatment images by an MLPNN.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8581277PMC
http://dx.doi.org/10.1016/j.adro.2021.100826DOI Listing

Publication Analysis

Top Keywords

intensity modulated
12
modulated proton
12
proton therapy
12
changes
9
dominant intraprostatic
8
intraprostatic lesion
8
anatomic changes
8
sib plans
8
planning computed
8
volume changes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!