Background: The dose distribution of heavy ions at the edge of the target region will have a steep decay during radiotherapy, which can better protect the surrounding organs at risk.
Objective: To analyze the dose decay gradient at the back edge of the target region during heavy ion radiotherapy.
Methods: Treatment planning system (TPS) was employed to analyze the dose decay at the edge of the beam under different incident modes and multiple dose segmentation conditions during fixed beam irradiation. The dose decay data of each plan was collected based on the position where the rear edge of the beam began to fall rapidly. Uniform scanning mode was selected in heavy ion TPS. Dose decay curves under different beam setup modes were drawn and compared.
Results: The dose decay data analysis showed that in the case of single beam irradiation, the posterior edge of the beam was 5 mm away, and the posterior dose could drop to about 20%. While irradiation in opposite direction, the posterior edge of the beam was 5 mm away, and the dose could drop to about 50%. In orthogonal irradiation of two beams, the posterior edge of the beam could drop to about 30-38% in a distance of 5 mm. Through the data analysis in the TPS, the sharpness of the dose at the back edge of the heavy ion beam is better than that at the lateral edge, but the generated X-ray contamination cannot be ignored.
Conclusions: The effect of uneven CT value on the dose decay of heavy ion beam should also be considered in clinical treatment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601813 | PMC |
http://dx.doi.org/10.1155/2021/4440877 | DOI Listing |
Int J Pharm
January 2025
Laboratory of Pharmaceutical Technology, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium. Electronic address:
In recent years, continuous manufacturing (CM) has become increasingly popular in the pharmaceutical industry for the production of oral solid dosage (OSD) forms. Most of the newly developed active pharmaceutical ingredients (APIs) nowadays are extremely cohesive and sticky with a mean particle size particle of <100μm, a wide particle size distribution (PSD) and a high tendency to agglomerate, making them difficult to accurately dose using loss-in-weight equipment during CM. In this research paper, the effect of various glidants on the volumetric and gravimetric feeding of several APIs was assessed.
View Article and Find Full Text PDFOpen Forum Infect Dis
January 2025
Infectious Disease Epidemiology and Analytics G5 Unit, Department of Global Health, Institut Pasteur, Université Paris-Cité, Paris, France.
Background: Establishing correlates of protection often requires large cohorts. A rapid and adaptable case-control study design can be used to identify antibody correlates of protection against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in serum and saliva.
Methods: We designed a case-control study to compare antibody levels between cases of SARS-CoV-2 infection within 5 days of symptom onset and uninfected controls.
Eur J Nucl Med Mol Imaging
January 2025
Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India.
Purpose: Enhancing therapeutic effectiveness is crucial for translating anticancer nanomedicines from laboratory to clinical settings. In this study, we have developed radioactive rhenium oxide nanoparticles encapsulated in human serum albumin ([Re]ReO-HSA NPs) for concurrent radiotherapy (RT) and photothermal therapy (PTT), aiming to optimize treatment outcomes.
Methods: [Re]ReO-HSA NPs were synthesized by a controlled reduction of ReO in HSA medium and extensively characterized.
Sci Rep
January 2025
Dep. Oral Biochemistry, Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, 1081, LA, The Netherlands.
The increasing use of recreational nitrous oxide ([Formula: see text]O) in the Netherlands and its link to traffic accidents highlights the need for reliable detection methods for law enforcement. This study focused on ex vivo detection of [Formula: see text]O in exhaled breath and examining its persistence in the human body. Firstly, a low-cost portable infrared based detector was selected and validated to detect [Formula: see text]O in air.
View Article and Find Full Text PDFAppl Radiat Isot
March 2025
Experimental Nuclear Physics Department, Nuclear Research Centre, Egyptian Atomic Energy Authority, Egypt; Cyclotron Facility, Egyptian Atomic Energy Authority, Egypt.
Neutron and gamma-ray shielding design for a 30Ci (1.11TBq) Am-Be irradiation facility is studied using MCNP5 Monte Carlo simulation code. The study focuses on the optimization of the shielding layers of the previously planned neutron irradiation facility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!