Analysis of the Dose Drop at the Edge of the Target Area in Heavy Ion Radiotherapy.

Comput Math Methods Med

Department of Heavy Ion Radiotherapy, Wuwei Tumor Hospital, No. 31 Sanitary Lane, Haizang Road, Wuwei City, Gansu Province, China 733000.

Published: February 2022

Background: The dose distribution of heavy ions at the edge of the target region will have a steep decay during radiotherapy, which can better protect the surrounding organs at risk.

Objective: To analyze the dose decay gradient at the back edge of the target region during heavy ion radiotherapy.

Methods: Treatment planning system (TPS) was employed to analyze the dose decay at the edge of the beam under different incident modes and multiple dose segmentation conditions during fixed beam irradiation. The dose decay data of each plan was collected based on the position where the rear edge of the beam began to fall rapidly. Uniform scanning mode was selected in heavy ion TPS. Dose decay curves under different beam setup modes were drawn and compared.

Results: The dose decay data analysis showed that in the case of single beam irradiation, the posterior edge of the beam was 5 mm away, and the posterior dose could drop to about 20%. While irradiation in opposite direction, the posterior edge of the beam was 5 mm away, and the dose could drop to about 50%. In orthogonal irradiation of two beams, the posterior edge of the beam could drop to about 30-38% in a distance of 5 mm. Through the data analysis in the TPS, the sharpness of the dose at the back edge of the heavy ion beam is better than that at the lateral edge, but the generated X-ray contamination cannot be ignored.

Conclusions: The effect of uneven CT value on the dose decay of heavy ion beam should also be considered in clinical treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601813PMC
http://dx.doi.org/10.1155/2021/4440877DOI Listing

Publication Analysis

Top Keywords

dose decay
24
heavy ion
20
edge beam
20
dose drop
12
edge target
12
posterior edge
12
dose
11
edge
10
beam
10
target region
8

Similar Publications

The impact of glidant addition on the loss-in-weight feeding of active pharmaceutical ingredients.

Int J Pharm

January 2025

Laboratory of Pharmaceutical Technology, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium. Electronic address:

In recent years, continuous manufacturing (CM) has become increasingly popular in the pharmaceutical industry for the production of oral solid dosage (OSD) forms. Most of the newly developed active pharmaceutical ingredients (APIs) nowadays are extremely cohesive and sticky with a mean particle size particle of <100μm, a wide particle size distribution (PSD) and a high tendency to agglomerate, making them difficult to accurately dose using loss-in-weight equipment during CM. In this research paper, the effect of various glidants on the volumetric and gravimetric feeding of several APIs was assessed.

View Article and Find Full Text PDF

Correlates of Protection Against Symptomatic COVID-19: The CORSER 5 Case-Control Study.

Open Forum Infect Dis

January 2025

Infectious Disease Epidemiology and Analytics G5 Unit, Department of Global Health, Institut Pasteur, Université Paris-Cité, Paris, France.

Background: Establishing correlates of protection often requires large cohorts. A rapid and adaptable case-control study design can be used to identify antibody correlates of protection against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in serum and saliva.

Methods: We designed a case-control study to compare antibody levels between cases of SARS-CoV-2 infection within 5 days of symptom onset and uninfected controls.

View Article and Find Full Text PDF

Purpose: Enhancing therapeutic effectiveness is crucial for translating anticancer nanomedicines from laboratory to clinical settings. In this study, we have developed radioactive rhenium oxide nanoparticles encapsulated in human serum albumin ([Re]ReO-HSA NPs) for concurrent radiotherapy (RT) and photothermal therapy (PTT), aiming to optimize treatment outcomes.

Methods: [Re]ReO-HSA NPs were synthesized by a controlled reduction of ReO in HSA medium and extensively characterized.

View Article and Find Full Text PDF

The increasing use of recreational nitrous oxide ([Formula: see text]O) in the Netherlands and its link to traffic accidents highlights the need for reliable detection methods for law enforcement. This study focused on ex vivo detection of [Formula: see text]O in exhaled breath and examining its persistence in the human body. Firstly, a low-cost portable infrared based detector was selected and validated to detect [Formula: see text]O in air.

View Article and Find Full Text PDF

Multi-layer shielding optimization of a high activity Am-Be mixed field irradiation facility.

Appl Radiat Isot

March 2025

Experimental Nuclear Physics Department, Nuclear Research Centre, Egyptian Atomic Energy Authority, Egypt; Cyclotron Facility, Egyptian Atomic Energy Authority, Egypt.

Neutron and gamma-ray shielding design for a 30Ci (1.11TBq) Am-Be irradiation facility is studied using MCNP5 Monte Carlo simulation code. The study focuses on the optimization of the shielding layers of the previously planned neutron irradiation facility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!