  • Noise-free ultrasound images are crucial for monitoring organs during regional therapy, but acoustic shadowing from bones can lead to missing information.
  • The study introduced a method utilizing a convolutional neural network for classifying acoustic shadow presence and created a composite shadow-free image by superimposing suitable images from a time-series database.
  • Results showed improved accuracy for kidney tracking, with enhanced image correlations, although further validation on real organs is needed.

Article Abstract

Purpose: Noise-free ultrasound images are essential for organ monitoring during regional ultrasound-guided therapy. When the affected area is located under the ribs, however, acoustic shadow is caused by the reflection of sound from hard tissues such as bone, and the image is output with missing information in this region. Therefore, in the present study, we attempt to complement the image in the missing area.

Methods: The overall flow of the complementation method to generate a shadow-free composite image is as follows. First, we constructed a binary classification method for the presence or absence of acoustic shadow on a phantom kidney based on a convolutional neural network. Second, we created a composite shadow-free image by searching for a suitable image from a time-series database and superimposing the corresponding area without shadow onto the missing area of the target image. In addition, we constructed and verified an automatic kidney mask generation method utilizing U-Net.

Results: The complementation accuracy for kidney tracking could be enhanced by template matching. Zero-mean normalized cross-correlation (ZNCC) values after complementation were higher than that of before complementation under four different data generation conditions: (i) changing the position of the bed of the robotic ultrasound diagnostic system in the translational direction, (ii) changing the probe angle in the translational direction, (iii) with the addition of rotational motion of the probe to condition (ii). Although there was large variation in the shape of the kidney contour in condition (iii), the proposed method improved the ZNCC value from 0.5437 to 0.5807.

Conclusions: The effectiveness of the proposed method was demonstrated in phantom experiments. Verification of its effectiveness in real organs is necessary in future study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-021-02525-8DOI Listing

Publication Analysis

Top Keywords

acoustic shadow
12
complementation method
8
convolutional neural
8
neural network
8
ultrasound-guided therapy
8
translational direction
8
proposed method
8
method
6
image
6
novel complementation
4

Similar Publications

Furuncular myiasis is a parasitic disease caused by the larvae of , or the human botfly, which burrow under the skin causing cystic lesions to develop. A six-year-old boy presented with multiple scalp lesions. The mother reported travel to Ecuador one month prior.

View Article and Find Full Text PDF

This study investigated the impact of bilateral bone conduction (BC) stimulation and sensorineural hearing loss on spatial release from masking, binaural intelligibility level difference, and lateralization. The study involved two groups of adults with mild to moderate sensorineural hearing loss: one group of 21 participants with symmetric hearing loss and another group of nine participants with asymmetric hearing loss. All tests were conducted through BC and air conduction (AC) headsets with non-individualized virtual positions of the sound sources and linear amplification based on individual hearing thresholds.

View Article and Find Full Text PDF

Background: Ovarian cancer remains a leading cause of death among women, largely due to its asymptomatic early stages and high mortality when diagnosed late. Early detection significantly improves survival rates, and the Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) is currently the most commonly used method, but has limitations in specificity and accuracy. While O-RADS US has standardized reporting, its sensitivity can lead to the misdiagnosis of benign masses as malignant, resulting in overtreatment.

View Article and Find Full Text PDF

Purpose: To evaluate the impact of intravascular ultrasound (IVUS)-evaluated tissue morphology on recurrence following drug-coated balloon (DCB) angioplasty for the treatment of femoropopliteal in-stent restenosis (FP-ISR).

Methods: This study was a single-center, retrospective, observational study. Study subjects were 65 FP-ISR lesions (mean lesion length: 165 ± 88 mm, occlusive restenosis: 25%) in 53 patients (age: 76 ± 8, diabetes mellitus: 66%) who underwent DCB angioplasty and whose IVUS data of tissue morphology were available.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how fine-needle aspiration biopsies (FNA) can lead to necrosis in thyroid tumors, making accurate diagnosis challenging, particularly in oncocytic tumors.
  • It includes a cross-sectional analysis of patients from 2011 to 2023, focusing on those with thyroid nodules that exhibited complete or near-complete necrosis, comparing ultrasound (US) features of these cases to controls.
  • Findings reveal that a "necrotic ring" on ultrasound shows high accuracy in predicting FNA-induced necrosis, especially when combined with a lack of blood flow within the nodule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!