Earlier studies that investigated the relation of atrioventricular (AV) conduction system to perimembranous ventricular septal defect (pmVSD) were based on cardiopathological specimens. To study the relationship of conduction system to pmVSD using 3-dimensional electroanatomic mapping system (EAMS) in patients undergoing device closure. Fifteen consecutive cases of pmVSD from January 2014 to July 2017 (age > 2 years and weight > 8 kg) were included in the study. The course of conduction system and its relationship with the pmVSD was mapped before and after device closure, with the use of EAMS. Median age and weight of the cohort was 10 years (range 4-21 years) and 25 kg (range 13-55) respectively. Device implantation was successful in all patients except 1. The course and relation of the conduction system were posteroinferior to the pmVSD in all cases (100%), and away from the defect in 67% (10/15). In patient with baseline RBBB, the right-sided conduction system was in close proximity to the pmVSD. Two patients had part of left-sided conduction system in close proximity to pmVSD or device edges. Two patients developed RBBB following device deployment, which reverted to normal on follow up. No patient developed high grade AV block during the median follow-up of 34 months (range 24-62). This experimental study has shown the feasibility of 3D EAM of conduction system during device closure of pmVSD. This novel concept can be utilized to understand the anatomy of conduction system in other congenital heart diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00246-021-02773-0DOI Listing

Publication Analysis

Top Keywords

conduction system
36
device closure
16
system
10
patients undergoing
8
perimembranous ventricular
8
ventricular septal
8
septal defect
8
conduction
8
pmvsd
8
system close
8

Similar Publications

Background: Little is known about the role that charitable copay assistance (CPA) plays in addressing access to care and financial distress. The study sought to evaluate financial distress and experience with CPA among patients with cancer and autoimmune disease.

Methods: This is a national cross-sectional self-administered anonymous electronic survey conducted among recipients of CPA to cover the costs of a drug for cancer or autoimmune disease.

View Article and Find Full Text PDF

Background: Mobile health apps have shown promising results in improving self-management of several chronic diseases in patients. We have developed a mobile health app (Cardiomeds) dedicated to patients with heart failure (HF). This app includes an interactive medication list; daily self-monitoring of symptoms, weight, blood pressure, and heart rate; and educational information on HF delivered through various formats.

View Article and Find Full Text PDF

Background: Chronic respiratory disorders such as asthma and chronic obstructive pulmonary disease (COPD) may deteriorate into acute exacerbations requiring hospitalization. Assessing the predictors of prolonged hospital stays could help identify potential interventions to reduce the burden on patients and healthcare systems.

Aim: This study aimed to identify the risk factors attributed to prolonged hospital stays among patients admitted with acute exacerbations of chronic respiratory disorders in Jordan.

View Article and Find Full Text PDF

Importance: Lung ultrasound (LUS) aids in the diagnosis of patients with dyspnea, including those with cardiogenic pulmonary edema, but requires technical proficiency for image acquisition. Previous research has demonstrated the effectiveness of artificial intelligence (AI) in guiding novice users to acquire high-quality cardiac ultrasound images, suggesting its potential for broader use in LUS.

Objective: To evaluate the ability of AI to guide acquisition of diagnostic-quality LUS images by trained health care professionals (THCPs).

View Article and Find Full Text PDF

Nondestructive Mechanical Characterization of Bioengineered Tissues by Digital Holography.

ACS Biomater Sci Eng

January 2025

Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, Massachusetts 01609, United States.

Mechanical properties of engineered connective tissues are critical for their success, yet modern sensors that measure physical qualities of tissues for quality control are invasive and destructive. The goal of this work was to develop a noncontact, nondestructive method to measure mechanical attributes of engineered skin substitutes during production without disturbing the sterile culture packaging. We optimized a digital holographic vibrometry (DHV) system to measure the mechanical behavior of Apligraf living cellular skin substitute through the clear packaging in multiple conditions: resting on solid agar as when the tissue is shipped, on liquid media in which it is grown, and freely suspended in air as occurs when the media is removed for feeding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!