Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This communication described how the Coris BioConcept COVID-19 Ag Respi-Strip test (Coris-Ag) was implemented in the workflow of our clinical microbiology laboratory for COVID-19 diagnosis. The diagnostic performance statistics (sensitivity, specificity) of the Coris-Ag were evaluated against a gold standard, the RealStar SARS-CoV-2 RT-PCR kit 1.0. Additionally, the effect of reading the Coris-Ag results at 30 min was compared to reading at 15 min. The Coris-Ag was performed on a total of 294 patients during two periods; 158 patients were tested during period 1 at the peak of the pandemic (April 6th to April 10th 2020) which returned a positivity rate of 17.1 %, and 136 patients during period 2 (April 12th to April 16th 2020) which returned a positivity rate of 11 %. Compared to the RT-PCR, the 15-minute Coris-Ag readings resulted in a sensitivity of 59.3 % with a 100 % specificity for the period 1 patients (n = 158) while the sensitivity decreased to 20 % for the period 2 patients (n = 136). The overall sensitivity was 38.1 % for both periods (n = 294). The corresponding 30-minute readings produced a 7 % increase in sensitivity with a specificity of 100 % (n = 294). The sensitivity of the strip test (15-min reading) for high viral loads (Ct <25) was 84.6 %.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8600801 | PMC |
http://dx.doi.org/10.1016/j.jviromet.2021.114366 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!