Automatic 3-D segmentation and volumetric light fluence correction for photoacoustic tomography based on optimal 3-D graph search.

Med Image Anal

School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China. Electronic address:

Published: January 2022

Preclinical imaging with photoacoustic tomography (PAT) has attracted wide attention in recent years since it is capable of providing molecular contrast with deep imaging depth. The automatic extraction and segmentation of the animal in PAT images is crucial for improving image analysis efficiency and enabling advanced image post-processing, such as light fluence (LF) correction for quantitative PAT imaging. Previous automatic segmentation methods are mostly two-dimensional approaches, which failed to conserve the 3-D surface continuity because the image slices were processed separately. This discontinuity problem further hampers LF correction, which, ideally, should be carried out in 3-D due to spatially diffused illumination. Here, to solve these problems, we propose a volumetric auto-segmentation method for small animal PAT imaging based on the 3-D optimal graph search (3-D GS) algorithm. The 3-D GS algorithm takes into account the relation among image slices by constructing a 3-D node-weighted directed graph, and thus ensures surface continuity. In view of the characteristics of PAT images, we improve the original 3-D GS algorithm on graph construction, solution guidance and cost assignment, such that the accuracy and smoothness of the segmented animal surface were guaranteed. We tested the performance of the proposed method by conducting in vivo nude mice imaging experiments with a commercial preclinical cross-sectional PAT system. The results showed that our method successfully retained the continuous global surface structure of the whole 3-D animal body, as well as smooth local subcutaneous tumor boundaries at different development stages. Moreover, based on the 3-D segmentation result, we were able to simulate volumetric LF distribution of the entire animal body and obtained LF corrected PAT images with enhanced structural visibility and uniform image intensity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.media.2021.102275DOI Listing

Publication Analysis

Top Keywords

pat images
12
3-d algorithm
12
3-d
10
3-d segmentation
8
light fluence
8
fluence correction
8
photoacoustic tomography
8
graph search
8
animal pat
8
pat imaging
8

Similar Publications

Thinning of anterolateral thigh flap is challenging. Anatomical studies have shown variations in arterial branching patterns in the subcutaneous layer, which were suspected to be the reason for the high frequency of thinning failures. We attempted to visualize subcutaneous arterial courses preoperatively and perform thinning of perforator flaps using this information appropriately.

View Article and Find Full Text PDF

Purpose: To quantitatively explore preretinal abnormal tissue (PAT) in macula-on rhegmatogenous retinal detachment (RRD) before and after surgery.

Methods: In this case-series study, PAT was detected by en-face optical coherence tomography images with custom slabs in eyes that underwent pars plana vitrectomy and SF6 for macula-on RRD.Main outcome measures were PAT area at baseline, 3-month and 6-month follow-up, and its relative change.

View Article and Find Full Text PDF

A self-assembled fluorescent nanoprobe recognized by FA1 site for specifically selecting HSA: Its applications in hemin detection, cell imaging and fluorescent tracing drug delivery.

Bioorg Chem

December 2024

Pancreas Center, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, State Key Laboratory of Druggability Evaluation and Systematic Translational Medicine, Tianjin Key Laboratory of Digestive Cancer, Tianjin's Clinical Research Center for Cancer, Tianjin 300060, China. Electronic address:

As naturally essential biomacromolecule, HSA has become diagnostic indicators for various diseases and universal carriers for anticancer drug delivery, therefore, fluorescence detection and labeling for HSA possess significant application value in the biomedical field. In this paper, hydrazide Schiff base fluorescent probe NDQC was designed and synthesized, which self-assembled into nanoparticles in aqueous solution system and demonstrated excellent selectivity and sensitivity towards HSA. Through displacement assay and molecular docking simulation, the binding of NDQC with HSA in FA1 site was demonstrated, thereby no obvious fluorescence signal presented for homologous protein BSA due to their structural differences in binding site.

View Article and Find Full Text PDF

What Is the Added Value of DWI Compared With Structured Assessment of BI-RADS Criteria by the Kaiser Score? A Systematic Review and Meta-analysis.

Invest Radiol

October 2024

From the Department of Radiology, University Hospital Erlangen, Erlangen, Germany (M.D.); and Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria (P.A.T.B., G.V.).

Objective: This systematic review and meta-analysis investigated the added value of DWI compared with the structured assessment of BI-RADS criteria using the Kaiser score.

Materials And Methods: Articles published in English until May 2024 were included. Two independent reviewers extracted data on the characteristics of studies evaluating the added value of DWI to distinguish benign from malignant breast lesions compared with structured assessment of the BI-RADS criteria.

View Article and Find Full Text PDF

Ovarian-adnexal lesions are conventionally assessed with ultrasound (US) under the guidance of the Ovarian-Adnexal Reporting and Data System (O-RADS). However, the low specificity of O-RADS results in many unnecessary surgeries. Here, we use co-registered US and photoacoustic tomography (PAT) to improve the diagnostic accuracy of O-RADS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!