Effect of data leakage in brain MRI classification using 2D convolutional neural networks.

Sci Rep

Department of Electrical, Electronic, and Information Engineering "Guglielmo Marconi", University of Bologna, Via dell'Università 50, 47521, Cesena, Italy.

Published: November 2021

In recent years, 2D convolutional neural networks (CNNs) have been extensively used to diagnose neurological diseases from magnetic resonance imaging (MRI) data due to their potential to discern subtle and intricate patterns. Despite the high performances reported in numerous studies, developing CNN models with good generalization abilities is still a challenging task due to possible data leakage introduced during cross-validation (CV). In this study, we quantitatively assessed the effect of a data leakage caused by 3D MRI data splitting based on a 2D slice-level using three 2D CNN models to classify patients with Alzheimer's disease (AD) and Parkinson's disease (PD). Our experiments showed that slice-level CV erroneously boosted the average slice level accuracy on the test set by 30% on Open Access Series of Imaging Studies (OASIS), 29% on Alzheimer's Disease Neuroimaging Initiative (ADNI), 48% on Parkinson's Progression Markers Initiative (PPMI) and 55% on a local de-novo PD Versilia dataset. Further tests on a randomly labeled OASIS-derived dataset produced about 96% of (erroneous) accuracy (slice-level split) and 50% accuracy (subject-level split), as expected from a randomized experiment. Overall, the extent of the effect of an erroneous slice-based CV is severe, especially for small datasets.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8604922PMC
http://dx.doi.org/10.1038/s41598-021-01681-wDOI Listing

Publication Analysis

Top Keywords

data leakage
12
convolutional neural
8
neural networks
8
mri data
8
cnn models
8
alzheimer's disease
8
data
5
leakage brain
4
brain mri
4
mri classification
4

Similar Publications

Introduction Anastomotic leakage (AL) following stoma closure is a significant complication that can lead to increased morbidity and mortality. Identifying risk factors associated with AL is essential for improving surgical outcomes, especially in resource-limited settings like Yemen. Methods We conducted this retrospective study at Al-Thawra Modern General Hospital and the Republican Teaching Hospital Authority in Sana'a, Yemen, between August 2020 and April 2024.

View Article and Find Full Text PDF

Magnetoelectric properties and Morin type spin transitions of Na-doped GaFeO.

J Phys Condens Matter

January 2025

Department of Physics, University of Kerala, Karyavattom 695581, Thiruvananthapuram, Kerala, India.

The effects of Na doping on the structure magnetic, electric, and magnetoelectric properties of GaFeOwere studied. Rietveld refinement of the XRD data reveals the formation of a single-phase trigonal structure with no impurity on Na doping up to 50% and a significant increase in lattice strain with doping. FTIR and Raman analysis further supported the phase purity of the samples.

View Article and Find Full Text PDF

The comprehensive adoption of Electronic Medical Records (EMRs) offers numerous benefits but also introduces risks of privacy leakage, particularly for patients with Sexually Transmitted Infections (STI) who need protection from social secondary harm. Despite advancements in privacy protection research, the effectiveness of these strategies in real-world data remains debatable. The objective is to develop effective information extraction and privacy protection strategies to safeguard STI patients in the Chinese healthcare environment and prevent unnecessary privacy leakage during the data-sharing process of EMRs.

View Article and Find Full Text PDF

Objectives: To assess the effectiveness of reinforcing sutures after surgery for rectal cancer and its associated impact on postoperative recovery. Anastomotic leakage (AL) is a common and serious complication after anteriorrectal resection. It is currently unclear whether laparoscopic intracorporeal reinforcingsutures can effectively reduce the incidence of AL.

View Article and Find Full Text PDF

Background: Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!