Evaluation of clinical parameters for the stability of 2 types of miniscrews.

Am J Orthod Dentofacial Orthop

Division of Orthodontics, College of Dentistry, The Ohio State University, Columbus, Ohio. Electronic address:

Published: March 2022

Introduction: The purpose of this research was to compare insertion techniques and effects on mechanical and clinical parameters between 2 types of miniscrews.

Methods: Forty-four consecutive patients whose orthodontic treatment involved the use of miniscrews (miniscrew A [MA] and miniscrew B [MB]) for anchorage were included in this study. Miniscrews were placed with predrilling or self-drilling; peak maximum insertion torque (MIT) and Periotest values were measured. Cone-beam computed tomography was performed after the insertion of miniscrews and root proximity determination; cortical bone thickness was also analyzed. Periotest values were measured after the application of orthodontic force.

Results: Self-drilling produced higher Periotest values (P <0.01) for MA and higher MIT (P <0.01) for MB with closer root proximity (P <0.05). MB had higher MIT and Periotest values with drilling compared with MA (P <0.05); MB also showed closer root proximity (P <0.05). Successful miniscrews had lower MIT (P <0.05) for MB and lower Periotest values (P <0.01) for both MA and MB, with significantly more distant root proximity (P <0.01). Self-drilling produced higher Periotest values at the time of placement (P <0.01) and after 4 weeks (P <0.05) in MA. Drilling produced higher Periotest values for MB at the time of placement (P <0.05). MIT had positive correlations with Periotest values for MB with self-drilling (P <0.01) and with root proximity for MA with drilling (P <0.01). Periotest values had negative correlations with root proximity for MA and the MB group with drilling (P <0.01).

Conclusions: For miniscrews with larger diameters, higher MIT may result in more mobility (higher Periotest values). Drilling can avoid root contact and enhance primary stability, thus producing lower Periotest values.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2020.09.035DOI Listing

Publication Analysis

Top Keywords

periotest values
12
clinical parameters
8
values measured
8
evaluation clinical
4
parameters stability
4
stability types
4
miniscrews
4
types miniscrews
4
miniscrews introduction
4
introduction purpose
4

Similar Publications

The purpose of this study was to determine the levels of IL-17, Bcl-3 and IκBζ gene expression in the gingival crevicular fluid (GCF) of psoriatic and healthy individuals and to compare the clinical periodontal parameters in the patient and control groups. A total of 10 psoriasis patients and 2 healthy patients in the control group were included in the analysis for IL-17, Bcl-3, and IκBζ gene expression in the GCF. Periodontal health, gingival index, plaque index, and mobility (using a periotest device) levels were compared between the groups.

View Article and Find Full Text PDF

The purpose of this study was to examine the impact of abutment screw head sizes on preload stability when secured to a standard external hex implant under oblique compressive forces. Fifteen metal crowns were divided into 3 equal groups. The first group had 5 angulated cemented crowns connected to a 3-mm-tall straight hexagonal abutment with an external hex abutment screw.

View Article and Find Full Text PDF

Conventional insertion torque and pull-out tests are destructive and unsuitable for clinical bone screw fixation. This study evaluates screw stability using acoustic modal analysis (AMA) and Periotest compared to traditional methods in an ex vivo animal model. Titanium self-tapping screws (STS) and nonself-tapping screws (N-STS) were implanted in the proximal tibia of 12 rabbits.

View Article and Find Full Text PDF

An In Vitro Evaluation of Periotest Implant Stability Measurements Taken on Implant Retained Crowns and Healing Abutments.

Clin Exp Dent Res

June 2024

Department of Restorative Dentistry and Periodontology, Dublin Dental University Hospital, University of Dublin, Trinity College, Dublin, Ireland.

Objective: To assess the reliability of implant stability measurements recorded with the Periotest device and to investigate the differences in values when these measurements were taken on implant retained crowns and healing abutments.

Materials And Methods: Fifty-six implants in eight synthetic bone blocks were used to carry out implant stability measurements using the Periotest device by two different operators. Each block constituted an example of bone of density D1, D2, D3, or D4, and two blocks of each density were used.

View Article and Find Full Text PDF

Correlation of sex hormone levels with orthodontic tooth movement in the maxilla: a prospective cohort study.

Eur J Orthod

June 2024

Department of Dentofacial Orthopaedics and Orthodontics, Wroclaw Medical University, Krakowska 26, 50-425 Wrocław, Poland.

Background: Sex hormones secreted during the menstrual cycle and the application of orthodontic forces to teeth can affect the metabolism of periodontal ligaments. This study aimed to determine whether there are any differences in orthodontic tooth displacement during the menstrual cycle and when using hormonal contraceptives and whether the amount of female sex hormones influences the efficiency of tooth displacement.

Methods: A total of 120 women aged between 20 and 30 years with Angle Class II requiring transpalatal arch (TPA) to derotate teeth 16 and 26 were included in this study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!