Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Raman spectroscopy is an inelastic light-scattering phenomenon that provides vibrational spectrum that contains information relative to chemical bonds and symmetry of a specific molecule, allowing the quali-quantitative simultaneous determination of several components in the biological fluids. Raman spectroscopy measurement returns a spectrum over a wavenumber range constituted by several bands representing biomarkers according to investigated biological matrices. In literature, it has been reported that at the frequencies inside the (1,300-1,360) cm total lipids, and tryptophan have been identified. On the basis of that, the aim of the present study was to compare the serum concentration of total lipids and tryptophan in horses subjected to a standardized obstacle course, in comparison with the data obtained in the (1,300-1,360) cm band. At this purpose, five clinically healthy and regularly trained Italian Saddle horses aged between 8, and 10 years old performed with the same rider an obstacle course of 350 m/min with twelve 1.30 m high jumps preceded by warm-up. Blood samples were collected by means of jugular venipuncture into a vacutainer tubes with clot activator at rest, after the exercise, and 30 minutes after the end of exercise. A high correlation was observed between the area of total lipids and tryptophan in the (1,300-1,360) cm band and their serum concentrations in all experimental conditions. Our preliminary results give a hint to study the exact correspondence between the area that identify these parameters in Raman spectrum and their serum concentration in athletic horses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jevs.2021.103820 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!