Motivated by possible atomic origins of the unidentified emission line detected at 3.55-3.57 keV in a stacked spectrum of galaxy clusters, an electron beam ion trap (EBIT) was used to investigate the resonant dielectronic recombination (DR) process in highly charged argon ions as a possible contributor to the emission feature. The He-like Ar DR-induced transition 1s2-1s23' was suggested to produce a 3.62 keV photon near the unidentified line at 3.57 keV and was the starting point of our investigation. The collisional-radiative model NOMAD was used to create synthetic spectra for comparison with both our EBIT measurements and with spectra produced with the AtomDB database/Astrophysical Plasma Emission Code (APEC) used in the Bulbul et al. work. Excellent agreement was found between the NOMAD and EBIT spectra, providing a high level of confidence in the atomic data used. Comparison of the NOMAD and APEC spectra revealed a number of missing features in the AtomDB database near the unidentified line. At an electron temperature of = 1.72 keV, the inclusion of the missing lines in AtomDB increases the total flux in the 3.5-3.66 keV energy band by a factor of 2. While important, this extra emission is not enough to explain the unidentified line found in the galaxy cluster spectra.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596318PMC
http://dx.doi.org/10.3847/1538-4357/ab0177DOI Listing

Publication Analysis

Top Keywords

dielectronic recombination
8
stacked spectrum
8
spectrum galaxy
8
galaxy clusters
8
kev
5
spectra
5
ebit
4
ebit observation
4
observation dielectronic
4
recombination lines
4

Similar Publications

Self-consistent and detailed opacities from a non-equilibrium average-atom model.

Philos Trans A Math Phys Eng Sci

August 2023

Pulsed Power Sciences Center, Sandia National Laboratories, Albuquerque, NM 87123, USA.

Modern density functional theory (DFT) is a powerful tool for accurately predicting self-consistent material properties such as equations of state, transport coefficients and opacities in high energy density plasmas, but it is generally restricted to conditions of local thermodynamic equilibrium (LTE) and produces only averaged electronic states instead of detailed configurations. We propose a simple modification to the bound-state occupation factor of a DFT-based average-atom model that captures essential non-LTE effects in plasmas-including autoionization and dielectronic recombination-thus extending DFT-based models to new regimes. We then expand the self-consistent electronic orbitals of the non-LTE DFT-AA model to generate multi-configuration electronic structure and detailed opacity spectra.

View Article and Find Full Text PDF

We experimentally show that the 1s^{2}2s^{2}2p_{1/2}-1s2s^{2}2p_{1/2}^{2} transition in Pb^{77+} emitted in dielectronic recombination of Pb^{78+} is strongly polarized, although it is an intrinsically unpolarized J=1/2 to 1/2 transition. This unanticipated polarization is shown to be due to quantum interference with radiative recombination. The interference effect has been studied on an asymmetric resonance profile but has never been studied on polarization.

View Article and Find Full Text PDF

An application of a Si/CdTe Compton camera for the polarization measurement of hard x rays from highly charged heavy ions.

Rev Sci Instrum

June 2021

Kavli Institute for the Physics and Mathematics of the Universe (WPI), Institutes for Advanced Study (UTIAS), The University of Tokyo, 5-1-5 Kashiwa-no-Ha, Kashiwa, Chiba 277-8583, Japan.

Methods to measure the polarization of x rays from highly charged heavy ions with a significantly higher accuracy than that of the existing technology are needed to explore relativistic and quantum electrodynamics effects, including the Breit interaction. We developed an Electron Beam Ion Trap Compton Camera (EBIT-CC), a new Compton polarimeter with pixelated multi-layer silicon, and cadmium telluride counters. The EBIT-CC detects the three-dimensional position of Compton scattering and photoelectric absorption, and thus, the degree of polarization of incoming x rays can be evaluated.

View Article and Find Full Text PDF

Motivated by possible atomic origins of the unidentified emission line detected at 3.55-3.57 keV in a stacked spectrum of galaxy clusters, an electron beam ion trap (EBIT) was used to investigate the resonant dielectronic recombination (DR) process in highly charged argon ions as a possible contributor to the emission feature.

View Article and Find Full Text PDF

The Heidelberg compact electron beam ion traps.

Rev Sci Instrum

June 2018

Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany.

Electron beam ion traps (EBITs) are ideal tools for both production and study of highly charged ions (HCIs). In order to reduce their construction, maintenance, and operation costs, we have developed a novel, compact, room-temperature design, the Heidelberg Compact EBIT (HC-EBIT). Four already commissioned devices operate at the strongest fields (up to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!