Background And Purpose: After aneurysmal SAH, transcranial Doppler is commonly used to monitor cerebral vasospasm. The diagnostic accuracy of transcranial Doppler flow velocity values in detecting angiographic vasospasm in patients requiring urgent endovascular intervention has not been established.

Materials And Methods: We performed a retrospective analysis of a consecutive series of patients with aneurysmal SAH who underwent transcranial Doppler (index test) within 24 hours of conventional angiography (reference test). The judgment of 33%, 50%, and 66% degree of vessel narrowing on angiography was independently established by multiple neuroendovascular clinicians. Vessel-specific per-segment and per-patient transcranial Doppler velocities were studied using receiver operating characteristic curves, the Youden index, and minimal acceptable sensitivity models. Optimal mean flow-velocity thresholds were explored to calculate sensitivity and specificity using a per-patient judgment of vasospasm of at least 50% angiographic narrowing in any large arterial segment except A1.

Results: In 221 patients, vasospasm was found in 15%, 8%, and 4% of arteries when the degree of reference angiographic luminal narrowing was 33%, 50%, and 66%, respectively. Mean flow velocities were significantly higher in vasospastic segments ( = . 001), but per-segment exploratory analyses yielded unsound mean flow velocity thresholds. The Youden and minimal acceptable sensitivity models proposed mean flow velocity thresholds of approximately 160 cm/s for the anterior circulation and 80 cm/s for the posterior circulation in the per-patient diagnosis of angiographic vasospasm (≥50%), yielding a sensitivity of 80%-90% (95% CI, 0.77-0.96), but with a corresponding specificity of 50% (95% CI, 0.40-0.56).

Conclusions: In this study, a threshold transcranial Doppler mean flow-velocity value that would accurately diagnose ≥50% angiographic vasospasm remained elusive.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757545PMC
http://dx.doi.org/10.3174/ajnr.A7347DOI Listing

Publication Analysis

Top Keywords

transcranial doppler
24
angiographic vasospasm
16
flow velocity
12
doppler velocities
8
diagnostic accuracy
8
aneurysmal sah
8
33% 50%
8
50% 66%
8
youden minimal
8
minimal acceptable
8

Similar Publications

Background And Purpose: While the pulsatility index (PI) measured by transcranial Doppler (TCD) has broader associations with outcomes in neurocritical care, its use in monitoring delayed cerebral infarction (DCI) in patients with aneurysmal subarachnoid hemorrhage (SAH) is not endorsed by current clinical guidelines. Recognizing that arterial pressure gradient (ΔP) can be estimated using PI, we investigated the potential significance of TCD-estimated ΔP.

Methods: In this observational study of 186 SAH patients, we recorded the mean cerebral blood flow velocity (mCBFV) and PI values from the middle cerebral artery, along with corresponding blood pressures.

View Article and Find Full Text PDF

Background: High variability of intracranial arterial blood flow velocities by Transcranial color-coded sonography (TCCS) has been found in clinical practice. This study aimed to improve diagnostic accuracy by analyzing influencing factors of middle cerebral artery (MCA) blood flow velocity detected by TCCS.

Methods: In total, 328 MCA vessels were classified as normal (27.

View Article and Find Full Text PDF

Objective: This study investigates cerebrovascular reactivity (CVR) changes in cryptogenic stroke (CS) patients with right-to-left shunts (RLS) and evaluates the relationship between CVR and white matter hyperintensities (WMHs).

Methods: The breath-holding index (BHI), representing CVR, was measured from the middle cerebral artery (MCA) using the breath-holding method. WMHs were defined as clearly hyperintense areas on 3T magnetic resonance imaging (MRI), assessed separately as periventricular hyperintensities (PVH) and deep white matter hyperintensities (DWMH).

View Article and Find Full Text PDF

Objective: To observe the clinical efficacy of 's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo (CV) and its effect on blood flow velocity of vertebral artery.

Methods: A total of 60 patients with CV were randomized into a Fu's subcutaneous needling group and a medication group, 30 cases in each one. In the Fu's subcutaneous needling group, 's subcutaneous needling was delivered at Dazhui (GV14), the flexible tube was retained for 5 min after sweeping manipulation, and the treatment was given once every other day, 3 times a week for 3 weeks.

View Article and Find Full Text PDF

In patients with acute brain injury (ABI), optimizing cerebral perfusion parameters relies on multimodal monitoring. This include data from systemic monitoring-mean arterial pressure (MAP), arterial carbon dioxide tension (PaCO), arterial oxygen saturation (SaO), hemoglobin levels (Hb), and temperature-as well as neurological monitoring-intracranial pressure (ICP), cerebral perfusion pressure (CPP), and transcranial Doppler (TCD) velocities. We hypothesized that these parameters alone were not sufficient to assess the risk of cerebral ischemia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!