A fully automatic system to assess foot collapse on lateral weight-bearing foot radiographs: A pilot study.

Comput Methods Programs Biomed

Division of Informatics, Imaging and Data Sciences, The University of Manchester, United Kingdom. Electronic address:

Published: January 2022

Background: Foot collapse is primarily diagnosed and monitored using lateral weight-bearing foot x-ray images. There are several well-validated measurements which aid assessment. However, these are subject to inter- and intra-user variability.

Objective: To develop and validate a software system for the fully automatic assessment of radiographic changes associated with foot collapse; automatically generating measurements for calcaneal tilt, cuboid height and Meary's angle.

Methods: This retrospective study was approved by the Health Research Authority (IRAS 244852). The system was developed using lateral weight-bearing foot x-ray images, and evaluated against manual measurements from five clinical experts. The system has two main components: (i) a Random Forest-based point-finder to outline the bones of interest; and (ii) a geometry-calculator to generate the measurements based on the point positions from the point-finder. The performance of the point-finder was assessed using the point-to-point error (i.e. the mean absolute distance between each found point and the equivalent ground truth point, averaged over all points per image). For assessing the performance of the geometry-calculator, linear mixed models were fitted to estimate clinical inter-observer agreement and to compare the performance of the software system to that of the clinical experts.

Results: A total of 200 images were collected from 79 subjects (mean age: 56.4 years ±12.9 SD, 30/49 females/males). There was good agreement among all clinical experts with intraclass correlation estimates between 0.78 and 0.86. The point-finder achieved a median point-to-point error of 2.2 mm. There was no significant difference between the clinical and automatically generated measurements using the point-finder points, suggesting that the fully automatically obtained measurements are in agreement with the manually obtained measurements.

Conclusions: The proposed system can be used to support and automate radiographic image assessment for diagnosing and managing foot collapse, saving clinician time, and improving patient outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8674729PMC
http://dx.doi.org/10.1016/j.cmpb.2021.106507DOI Listing

Publication Analysis

Top Keywords

foot collapse
16
lateral weight-bearing
12
weight-bearing foot
12
fully automatic
8
foot x-ray
8
x-ray images
8
software system
8
clinical experts
8
point-to-point error
8
foot
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!